Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Refactoring of LEC/SEC scripts #928

Closed
wants to merge 1 commit into from
Closed
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
51 changes: 0 additions & 51 deletions scripts/lec/README.md

This file was deleted.

22 changes: 0 additions & 22 deletions scripts/lec/clone_reference.sh

This file was deleted.

98 changes: 0 additions & 98 deletions scripts/lec/lec.sh

This file was deleted.

22 changes: 0 additions & 22 deletions scripts/lec/synopsys_formality/check_lec.tcl

This file was deleted.

58 changes: 58 additions & 0 deletions scripts/slec/README.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,58 @@
# Sequential Logic Equivalence Checking (SLEC)

This folder contains a SLEC script that runs:

- LEC: Synopsys Formality and Cadence Design Systems Conformal.
- SEC: Siemens SLEC App

Please have a look at: https://cv32e40p.readthedocs.io/en/latest/core_versions/

The `cv32e40p_v1.0.0` tag refers to the frozen RTL. The RTL has been verified
and frozen on a given value of the input parameter of the design. Unless a bug
is found, it is forbidden to change the RTL in a non-logical equivalent manner
for PPA optimizations of any other change.
Instead, it is possible to change the RTL on a different value of the parameter
set, which has not been verified yet.
For example, it is possible to change the RTL design when the `FPU` parameter is
set to 1 as this configuration has not been verified yet. However, the design
must be logically equivalent when the parameter is set back to 0.
It is possible to change the `apu` interface and the `pulp_clock_en_i` signal on
the frozen parameter set as these signals are not used when the parameter `FPU`
and `PULP_CLUSTER` are set to 0, respectively.

The current scripts have been tried on Synopsys Formality `2021.06-SP5` ,
Cadence Design Systems Conformal `20.20` and Siemens SLEC App `2023.4`.

### Running the script

From a bash shell using LEC, please execute:

```
./run.sh -t synopsys -p lec
```
or

```
./run.sh -t cadence -p lec
```

From a bash shell to use SEC, please execute:
```
./run.sh -t siemens -p sec
```

The script clones the `cv32e40p_v1.0.0` tag of the core as a golden reference,
and uses the current repository's `rtl` as revised version.

If you want to use another golden reference RTL, Set the `GOLDEN_RTL`
environmental variable to the new RTL before calling the `run.sh` script.

```
export GOLDEN_RTL=YOUR_GOLDEN_CORE_RTL_PATH
```
or

```
setenv GOLDEN_RTL YOUR_GOLDEN_CORE_RTL_PATH
```

Original file line number Diff line number Diff line change
Expand Up @@ -11,12 +11,13 @@
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
// See the License for the specific language governing permissions and
// limitations under the License.
set summary_log $::env(summary_log)

read_design -SV -replace -noelaborate -golden -File ../golden.src
read_design -SV -replace -noelaborate -golden -File ./golden.src

elaborate_design -golden

read_design -SV -replace -noelaborate -revised -File ../revised.src
read_design -SV -replace -noelaborate -revised -File ./revised.src

elaborate_design -revised

Expand All @@ -31,8 +32,8 @@ write_hier_compare_dofile hier_compare_r2r.do -constraint -replace

run_hier_compare hier_compare_r2r.do -ROOT_module cv32e40p_core cv32e40p_core

report_hier_compare_result -all -usage > ./reports/result.rpt
report_hier_compare_result -NONEQuivalent -usage > ./reports/result_noneq.rpt
report_verification -verbose -hier > ./reports/result_verfication.rpt
report_hier_compare_result -all -usage > $sumary_log
report_verification -verbose -hier >> $sumary_log
report_hier_compare_result -NONEQuivalent -usage > $sumary_log.noneq.rpt

exit 0
Loading
Loading