This is a Node.JS module for interfacing with Pentair ScreenLogic systems over your local network or remotely through the Pentair dispatcher. Local connections require a Pentair ScreenLogic device on the same network (a network which supports UDP broadcasts).
Tested with a Pentair ScreenLogic system on firmware versions 5.2 Build 736.0 Rel, 5.2 Build 738.0 Rel
See the Wiki for information on migrating from v1 to v2.
Table of Contents:
- Usage
- Notes
- Packet format
- API reference
See example.ts for an example of interfacing with the library. Broadly, import the library with
import * as Screenlogic from "./index";
Individual named imports can also be used. Then for local connections create a new ScreenLogic unit finder with
let finder = new ScreenLogic.FindUnits();
let localUnit = await finder.searchAsync();
return Promise.resolve(localUnit);
If you prefer to use an event-based approach, you can hook the serverFound
event with:
.on('serverFound', function(server) { })
await finder.searchAsync();
and call it via searchAsync()
. This performs a UDP broadcast on 255.255.255.255, port 1444, so ensure your network supports UDP broadcasts and the device is on the same subnet.
Alternatively, to find a unit remotely, create a new ScreenLogic remote login with
let gateway = new ScreenLogic.RemoteLogin(systemName); // systemName in the format "Pentair: xx-xx-xx"
let unit = await gateway.connectAsync();
if (!unit || !unit.gatewayFound || unit.ipAddr === '') {
logger.error(`Screenlogic: No unit found called ${systemName}`);
return;
}
await gateway.closeAsync();
and call it via connectAsync()
. This opens a TCP connection to screenlogicserver.pentair.com, port 500.
When a local or remote server is found, create and connect to a new UnitConnection with
let client = ScreenLogic.screenlogic;
client.init(systemName, ipAddr, port, password); // ipAddr and password as strings; port as integer
await client.connectAsync();
where password
is the remote login password.
Once you've connected with connectAsync()
, there are a number of methods available and corresponding events for when they've completed successfully. See screenlogic API reference.
All communication with a ScreenLogic unit is done via TCP, so responses will come back in the order they were requested.
Contributions welcome. There are lots of available messages supported by ScreenLogic that the app doesn't support yet, but can be added pretty easily as needed.
All ScreenLogic packets are sent with an 8-byte header. The first 2 bytes are a little-endian-encoded sender ID (which is normally specified when making the original request). The second 2 bytes are a little-endian-encoded message ID. The final 4 bytes are a little-endian-encoded length of the data payload on the packet. The data payload is handled per-message.
Pull requests to document undocumented properties are most welcome.
Examples:
import * as Screenlogic from 'node-screenlogic';
/*or
const ScreenLogic = require('node-screenlogic');
*/
var finder = new ScreenLogic.FindUnits();
Issues one UDP broadcast search for available units. Since this is a stateless UDP query, the connection will not automatically be closed, so you may need to issue another search if the first one doesn't work, if your network connection is not established, etc. There is no automatic timeout built in to this command. This call does not return any found units directly, but does emit the serverFound
message which contains each LocalUnit object that is found:
address
- ip address stringtype
- integerport
- integer, the port to connect togatewayType
- integergatewaySubtype
- integergatewayName
- the gateway/unit name as a string
Issues one UDP broadcast search for available units. This is a stateless UDP query, but the connection will automatically be closed, so you may need to issue another search if the first one doesn't work, if your network connection is not established, etc. There is a 5s timeout built in to this command, and no retry mechanism.
Optionally accepts a number of milliseconds to wait for units; defaults to 5000 if not specified. Returns a LocalUnit[] array with each object containing:
address
- ip address stringtype
- integerport
- integer, the port to connect togatewayType
- integergatewaySubtype
- integergatewayName
- the gateway/unit name as a string
This async call will also emit the serverFound
message.
Closes the socket. Only needed for search(). searchAsync() will close the socket itself.
close
- Indicates thatclose()
has been called on the finder.error
- Indicates that an unhandled error was caught (such as the connection timing out).serverFound
- Indicates that a ScreenLogic unit has been found. Event handler receives a UnitConnection object. The async call is a wrapper for this event.
Examples:
let finder = new ScreenLogic.FindUnits();
let localUnit = await finder.searchAsync();
// or hook the event if you don't assign the function to a variable
finder.on('serverFound', function(server) {
// server object will contain connection information
})
Argument is the name of a system to connect to in "Pentair: xx-xx-xx" format.
Example:
let gateway = new ScreenLogic.RemoteLogin(systemName); // systemName in the format "Pentair: xx-xx-xx"
let unit = await gateway.connectAsync();
if (!unit || !unit.gatewayFound || unit.ipAddr === '') {
logger.error(`Screenlogic: No unit found called ${systemName}`);
return;
}
await gateway.closeAsync();
// or use the emit if you don't assign the function to a variable
Connects to the dispatcher service and searches for the unit passed to its constructor.
Closes the connection and removes all listeners.
close
- Indicates that the connection to the remote login server has been closed. Event handler receives a bool indicating whether there was a transmission error.end
- Indicates the socket has terminated.error
- Indicates that an unhandled error was caught (such as the connection timing out).timeout
- Indicates the socket timed out.clientError
- Indicates an error with the client on the other end of the socket.gatewayFound
- Indicates that the search for the named unit has completed (may or may not be successful). Event handler receives a SLReceiveGatewayDataMessage argument. The async function is a promise that wraps this event.
screenlogic
is an exported module that maintains state and connection for a given unit. Parameters are initialized with the init
and connections are made with the connectAsync
functions.
Examples:
let client = ScreenLogic.screenlogic;
client.init(systemName, unit.ipAddr, unit.port, password);
await client.connectAsync();
Takes the parameters (systemName, address, port, password, senderId?)
systemName is a string. Port is an integer. Address is an IPv4 address of the server as a string. Password is optional; should be the 4-digit password in string form, e.g. '1234'
.
senderId
can be set once (or it defaults to 0) and will be present as the senderId
field on the returned message.
Examples:
client.init('Pentair: 00-00-00', '10.0.0.85', 80, '1234', senderId?);
Helper method for init. Takes a LocalUnit
remote login object and passes the appropriate values to init
.
Connects to the server after init
parameters are set.
Examples:
await client.connectAsync();
Closes the connection and removes all listeners.
Registers to receive updates from controller when something changes. Takes a random number clientId
(if passed, or will be randomly assigned) to identify the client. Resolves/emits the addClient
event when the request to add a client is acknowledged. As long as this client is connected, various events will be emitted when something changes on the controller, such as equipmentState
or chemicalData
.
Requests the system version string from the connected unit. Resolves/emits the version
event when the response comes back.
Sends a ping to the server to keep the connection alive. Resolves/emits the pong
event when the response comes back.
Will be automatically called if node-screenlogic detects an error in communications, but can also be called manually to re-establish communications.
No longer receive update messages from controller. Resolves/emits the removeClient
event when the request to remove a client is acknowledged. clientId
must match a client previously registered via addClientAsync().
Returns an object with the socket state:
destroyed
- boolean indicating if the socket has been destroyedconnecting
- boolean indicating if the socket is in a connecting statetimeout
- optional boolean indicating if the socket timed outreadyState
- string
Sets the cooling setpoint for any body. Emits the coolSetPointChanged
event when response is acknowledged. Resolves with BoolData.
Parameters:
bodyId
- integer indicating the type of body to set the setpoint of. The pool is body0
and the spa is body1
.temperature
- integer indicating the desired setpoint. This is presumably in whatever units your system is set to (celsius or fahrenheit).
Sets the preferred heat mode. See SLSetHeatModeMessage documentation for argument values. Emits the heatModeChanged
event when response is acknowledged. Resolves with BoolData.
Sets the heating setpoint for any body. Emits the setPointChanged
event when response is acknowledged. Resolves with BoolData.
Parameters:
bodyId
- integer indicating the type of body to set the setpoint of. The pool is body0
and the spa is body1
.temperature
- integer indicating the desired setpoint. This is presumably in whatever units your system is set to (celsius or fahrenheit).
Requests chemical history data from the connected unit. This is information about the pH and ORP readings over time and when pH and ORP feeds were turned on and off. fromTime
is the time (as a Javascript Date object) that you want to get events from and toTime
is the time (as a Javascript Date object) that you want to get events until. If omitted, data will be resolved for the past 24 hours. Emits the getChemHistoryDataPending
event when the request to get data is confirmed, then the getChemHistoryData
event when the chemical history data is actually ready to be handled. Resolves with SLChemHistory.
Requests chemical data from the connected unit (may require an IntelliChem or similar). Emits the chemicalData
event when the response comes back. Resolves with SLChemData.
Requests salt cell status/configuration from the connected unit (requires an IntelliChlor or compatible salt cell). Emits the intellichlorConfig
event when the response comes back. Resolves with SLIntellichlorData.
Tells the OCP if a chlorinator is present. isActive
is a boolean. Emits the intellichlorIsActive
event. Resolves with BoolData.
Sets the salt cell's output levels. See SLSetIntellichlorConfigMessage documentation for argument values. Emits the setIntellichlorConfig
event when response is acknowledged. Resolves with BoolData.
Sends a lighting command. See SLLightControlMessage documentation for argument values. Emits the sentLightCommand
event when response is acknowledged. Resolves with BoolData.
EasyTouch/Intellitouch only have a single light group and individual lights cannot be address. Pentair's Intellicenter offers this capability.
circuits.setCircuitAsync(circuitId, nameIndex, circuitFunction, circuitInterface, freeze, colorPos, senderId?)
Parameters:
circuitId
- 1 based index of circuit id'snameIndex
- 1 based index of the name id (built-in or custom)circuitFunction
- Number from getCircuitDefinitionsAsynccircuitInterface
- 0 = pool; 1 = spa; 2 = features; 4 = lights; 5 = hidefreeze
- boolean. Turn this circuit on with freeze protection.colorPos
- Number. Only applicable for Intellibrite.
Sets the configuration for a specific circuit. Emits the circuit
event when completed. Resolves with BoolData.
Configures default run-time of a circuit, usually referred to as the 'egg timer'. This also applies to 'run-once' programs as this will set the length of the program. See SLSetCircuitRuntimeById documentation for argument values. Emits the setCircuitRuntimeById
event when response is acknowledged. Resolves with BoolData.
Activates or deactivates a circuit. See SLSetCircuitStateMessage documentation for argument values. Emits the circuitStateChanged
event when response is acknowledged. Resolves with BoolData.
Cancels any delays on the system. Resolves as a BoolData and emits the cancelDelay
event when response is acknowledged.
Returns an array of objects that represent the different circuit functions that a circuit can be assigned. Emits the circuitDefinitions
event which resolves to a SLCircuitNamesData object.
Returns an array of objects with circuit names and IDs. Internally, this calls equipment.getNCircuitNames() for the count of circuits and equipment.getCircuitNames(index, count) to retrieve the array from the server. Emits the circuitNames
event which resolves with a SLCircuitNamesData object.
Requests controller configuration from the connected unit. Emits the controllerConfig
event when the response comes back. Resolves with EquipmentConfigurationMessage.
Requests all custom names from the OCP. An array of 20 names will be returned, but some OCP's only support 10. Emits the getCustomNames
event. Resolves with SLGetCustomNamesData.
Resolves/emits the equipmentConfiguration
event when the response comes back. This is the basic configuration of what equipment is installed on the controller. Resolves with SLEquipmentConfigurationData.
Emits the equipmentState
event when the response comes back. This is the current state of all equipment in the system. Resolves with SLEquipmentStateMessage.
Requests history data from the connected unit. This is information like what various temperature sensors (air, water) read over time, changes in heat setpoints, and when various circuits (pool, spa, solar, heater, and lights) were turned on and off. fromTime
is the time (as a Javascript Date object) that you want to get events from and toTime
is the time (as a Javascript Date object) that you want to get events until. Will default to the last 24 hours if fromTime/toTime are not provided. Resolves/emits the getHistoryDataPending
event when the request to get data is confirmed, then the getHistoryData
event when the history data is actually ready to be handled. Resolves with SLHistoryData.
Retrieves the current time the system is set to. Emits the getSystemTime
event when response is received. Resolves with SLSystemTimeData.
Requests the system version string from the connected unit. Emits the weatherForecast
event when the response comes back. Resolves with SLWeatherForecastData.
Sets an individual custom name on the OCP. idx
is the index of the custom name, name
is the custom name to be set, senderId
is the optional unique identifier. Emits the setCustomName
event. Resolves with BoolData.
This method allows you to set the configuration of the controller. data
is in the format of SLEquipmentConfigurationData
but will take any individual component, or all components. Emits the setEquipmentConfiguration
event which resolves with SLSetEquipmentConfigurationData.
Sets the current date and time of the ScreenLogic system. Resolves/emits the setSystemTime
event when request is acknowledged. date
must be a Date
instance holding the date/time to set, and adjustForDST
must be a boolean indicating whether the system should adjust for daylight saving time or not. Resolves with SLSystemTimeData.
Gets information about the specified pump (1 based index). See SLPumpStatusData documentation for argument values. Resolves/emits the getPumpStatus
event when response is acknowledged.
Parameters:
pumpId
- id of pump to get information about, first pump is 0circuitId
- index of circuit for which to change the set point (id of the pump as returned by SLPumpStatusData)speed
- the value for which to set the pump/circuit comboisRPMs
- optional (will be inferred). boolean,true
for RPMs,false
for GPMs
Sets speed (rpm) or flow (gpm) setting for a pump/circuit combination. Emits the setPumpSpeed
event when response is acknowledged. Resolves with BoolData.
Parameters:
scheduleType
- 0 indicates recurring scheduled events, 1 indicates a run-once event
Adds a new event to the specified schedule type. Emits either the addNewScheduleEvent
, with NumberData, or scheduleChanged
event when response is acknowledged (listen for both).
Parameters:
scheduleType
- 0 indicates recurring scheduled events, 1 indicates a run-once event
Deletes a scheduled event with specified id. Resolves/emits the deleteScheduleEventById
, with BoolData, or scheduleChanged
event when response is acknowledged (listen for both).
Parameters:
scheduleType
- 0 indicates recurring scheduled events, 1 indicates a run-once event
Retrieves a list of schedule events of the specified type. Emits the getScheduleData
event when response is acknowledged. Resolves with an SLScheduleData array.
schedule.setScheduleEventByIdAsync(scheduleId, circuitId, startTime, stopTime, dayMask, flags, heatCmd, heatSetPoint, senderId?)
Configures a schedule event. See SLSetScheduleEventById documentation for argument values. Resolves/emits the setScheduleEventById
or scheduleChanged
event when response is acknowledged (listen for both). Resolves with BoolData.
addClient
- Indicates that a response toaddClientAsync()
has been received. Event handler receives a SLAddClient object.addNewScheduleEvent
- Indicates that a response toaddNewScheduleEventAsync()
has been received which contains the createdscheduleId
to be used later for setting up the properties. Event handler receives a NumberData object.badParameter
- Indicates that a bad parameter has been supplied to a function. This can be triggered, for example, by sending the wrong controller ID to aset
function.cancelDelay
- Indicates that a response tocancelDelayAsync()
has been received. Event handler receives a BoolData.chemicalData
- Indicates that a response togetChemicalDataAsync()
has been received. Event handler receives a SLChemData object.circuitStateChanged
- Indicates that a response tosetCircuitStateAsync()
has been received. Event handler receives a SLSetCircuitStateMessage object.close
- Indicates that the connection to the unit has been closed. Event handler receives a bool indicating whether there was a transmission error.controllerConfig
- Indicates that a response togetControllerConfigAsync()
has been received. Event handler receives a EquipmentConfigurationMessage object.coolSetPointChanged
- Indicates that a response tosetCoolSetPointAsync()
has been received. Event handler receives a BoolData object.deleteScheduleById
- Indicates that a response todeleteScheduleByIdAsync()
has been received. Event handler receives a SLDeleteScheduleEventById object.error
- Indicates that an unhandled error was caught (such as the connection timing out)equipmentConfiguration
- Indicates a response togetEquipmentConfigurationAsync()
. Receives a SLEquipmentConfigurationData object.equipmentState
- Indicates that a response togetEquipmentStateAsync()
has been received. Event handler receives a SLEquipmentStateMessage object.getChemHistoryData
- Indicates that chemical history data for the requested timeframe is ready. Event handler receives a SLGetChemHistoryData object.getChemHistoryDataPending
- Indicates that thegetChemHistoryDataAsync()
request has been received and is being processed.getHistoryData
- Indicates that history data for the requested timeframe is ready. Event handler receives a SLHistoryData object.getHistoryDataPending
- Indicates that thegetHistoryDataAsync()
request has been received and is being processed.getPumpStatus
- Indicates that a response togetPumpStatusAsync()
has been received. Event handler receives a SLPumpStatusData object.getScheduleData
- Indicates that a response togetScheduleDataAsync()
has been received. Event handler receives a SLGetScheduleData object.getSystemTime
- Indicates that a response togetSystemTimeAsync()
has been received. Event handler receives a SLSystemTimeData object.heatModeChanged
- Indicates that a response tosetHeatModeAsync()
has been received. Event handler receives a SLSetHeatModeMessage object.intellichlorConfig
- Indicates that a response togetIntellichlorConfigAsync()
has been received. Event handler receives a SLIntellichlorConfigMessage object.loggedIn
- Indicates that a connection to the server has been established and the login process completed.get
methods can be called once this event has been emitted.loginFailed
- Indicates that a remote login attempt via supplying a system address and password toUnitConnection
has failed likely due to the incorrect password being used.pong
- Indicates that a response topingServerAsync()
has been received. Event handler receives a SLPingServerMessage object.removeClient
- Indicates that a response toremoveClientAsync()
has been received. Event handler receives a SLRemoveClient object.scheduleChanged
- Indicates that a response to adding, deleting, or setting a schedule has been received. Event handler receives nothing. This seems to be arbitrarily returned sometimes instead of a normal ack by the system.sentLightCommand
- Indicates that a response tosendLightCommandAsync()
has been received. Event handler receives a SLLightControlMessage object.setCircuitRuntimeById
- Indicates that a response tosetCircuitRuntimeByIdAsync()
has been received. Event handler receives a SLSetCircuitRuntimeById object.setEquipmentConfiguration
- Indicates that the last call tosetEquipmentConfigurationAsync()
has been applied. Event handler receives a SLSetEquipmentConfigurationData object.setEquipmentConfigurationAck
- Indicates that the request tosetEquipmentConfigurationAsync()
has been received. Event handler receives a BoolData object.setIntellichlorConfig
- Indicates that a response tosetIntellichlorOutputAsync()
has been received. Event handler receives a SLSetIntellichlorConfigMessage object.setPumpSpeed
- Indicates that a response tosetPumpFlowAsync()
has been received. Event handler receives a BoolData object.setPointChanged
- Indicates that a response tosetSetPointAsync()
has been received. Event handler receives a SLSetHeatSetPointMessage object.setScheduleEventById
- Indicates that a response tosetScheduleEventByIdAsync()
has been received. Event handler receives a SLSetScheduleEventById object.setSystemTime
- Indicates that a response tosetSystemTimeAsync()
has been received. Event handler receives a BoolData object if the request was valid, ornull
/rejected promise if the request was invalid (input parameters were not of the required types).unknownCommand
- Indicates that an unknown command was issued to ScreenLogic (should not be possible to trigger when using the suppliedUnitConnection
methods).version
- Indicates that a response togetVersionAsync()
has been received. Event handler receives a SLVersionMessage object.
address
- string representing the IPv4 address of the found servertype
- integer representing the type of server found (will always be 2)port
- short representing the port to use for TCP connections to this servergatewayType
- bytegatewaySubtype
- bytegatewayName
- string representing the server's name. Will be in the format Pentair: xx-xx-xx
Information about features common to all the below SL Message types.
Interprets a time integer recorded as minutes past midnight and returns the ScreenLogic string representation of it in 24-hour time.
Interprets the string representing 24-hour time and returns an integer of minutes past midnight.
Converts a day mask from, for example, SLGetScheduleData
's events[idx].days property into a DAY_VALUES
array for ease of use.
Converts an array of DAY_VALUES
keys (['Mon', 'Tue']
, etc.) into a mask used by, for example, SLGetScheduleData
's events[idx].days property.
Returns the value of a given DAY_VALUES
day name.
DAY_VALUES
is defined as the following map for simplicity of checking whether a specific day is set in a mask:
const DAY_VALUES = {
Mon: 0x1,
Tue: 0x2,
Wed: 0x4,
Thu: 0x8,
Fri: 0x10,
Sat: 0x20,
Sun: 0x40,
};
senderId
- an integer matching whatever was passed as thesenderId
argument when making the initial request (default 0)action
- an integer indicating the ScreenLogic ID for this message
Generic response type that holds the sender id of the request and a boolean value.
senderId
- the sender id from the matching requestval
- boolean value
Generic response type that holds the sender id of the request and a number value.
senderId
- the sender id from the matching requestval
- number value
Passed as an argument to the emitted addClient
event.
Passed as an argument to the emitted cancelDelay
event.
Passed as an argument to the emitted chemicalData
event handler.
isValid
- boolean indicating whether we got a valid response back or notpH
- float indicating the current pH levelorp
- short indicating the current ORP levelpHSetPoint
- float indicating the desired pH levelorpSetPoint
- short indicating the desired ORP levelpHTankLevel
- byte indicating how full the pH tank is. I believe this operates on a 0-6 scaleorpTankLevel
- byte indicating how full the ORP tank issaturation
- float indicating water balance/LSI saturationcalcium
- short indicating the calcium level (manually set)cyanuricAcid
- short indicating the CYA level (manually set)alkalinity
- short indicating the alkalinity level (manually set)saltPPM
- integer representing the salt level in parts-per-milliontemperature
- byte indicating the current water temperaturecorrosive
- boolean indicating whether the water balance is corrosive or notscaling
- boolean indicating whether the water balance is scaling or noterror
- boolean indicating whether there's currently an error in the chem system or notbalance
- bitmask containing the composite data that is broken out tocorrosive
,scaling
, anderror
- generally you should prefer to use those properties instead
circuits
- an array of circuit ids to namesid
- number indicating the id of the circuitcircuitName
- string indicating the circuit's name
Passed as an argument to the emitted controllerConfig
event handler.
Returns a bool indicating whether the system is an EasyTouch system or not. (Helper method for interpreting the value in controllerType
.)
Returns a bool indicating whether the system is an IntelliTouch system or not. (Helper method for interpreting the value in controllerType
.)
Returns a bool indicating whether the system is an EasyTouch Lite system or not. (Helper method for interpreting the value in controllerType
and hwType
.)
Returns a bool indicating whether the system is dual-body or not. (Helper method for interpreting the value in controllerType
.)
Returns a bool indicating whether the system is a Chem2 system or not. (Helper method for interpreting the value in controllerType
and hwType
.)
controllerId
- integer indicating the id of the controllerminSetPoint
- array (size 2) indicating the minimum setpoint available for the pool (index 0) or spa (index 1)maxSetPoint
- array (size 2) indicating the maximum setpoint available for the pool (index 0) or spa (index 1)degC
- boolean indicating whether the system is using the centigrade scale for temperatures or notcontrollerType
- byte that can be passed to static methods to interpret what type of controller this iscircuitCount
- integer indicating the size of the circuitArraycircuitArray
- array holding circuit datacircuitId
- numbername
- stringnameIndex
- numberfunction
- numberinterface
- numberfreeze
- numbercolorSet
- numbercolorPos
- numbercolorStagger
- numberdeviceId
- numbereggTimer
- number
hwType
- byte passed to static methods to determine more info about the hardwarecontrollerData
- byteequipment
- object containing booleans that provide additional data about available equipmentPOOL_SOLARPRESENT
- boolean indicating if solar is presentPOOL_SOLARHEATPUMP
- boolean indicating if a solar heat pump is presentPOOL_CHLORPRESENT
- boolean indicating if a chlorinator is presentPOOL_IBRITEPRESENT
- boolean indicating if IntelliBrite is presentPOOL_IFLOWPRESENT0
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT1
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT2
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT3
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT4
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT5
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT6
- boolean indicating if IntelliFlow pumps are presentPOOL_IFLOWPRESENT7
- boolean indicating if IntelliFlow pumps are presentPOOL_NO_SPECIAL_LIGHTS
- boolean indicating if there are no special lights presentPOOL_HEATPUMPHASCOOL
- boolean indicating if the heat pump has a cooling featurePOOL_MAGICSTREAMPRESENT
- boolean indicating if MagicStream deck jets are presentPOOL_ICHEMPRESENT
- boolean indicating if an IntelliChem is present
genCircuitName
- string indicating the circuit nameinterfaceTabFlags
- integercolorCount
- integer indicating the size of the colorArray arraycolorArray
- array holding light color informationname
- string indicating the light namecolor
- object containing color datar
- byte indicating red value from 0-255g
- byte indicating green value from 0-255b
- byte indicating blue value from 0-255
pumpCircCount
- integer indicating the size of the pumpCircArray arraypumpCircArray
- array of numbers indicating ids of pump circuitsshowAlarms
- integer
Passed as an argument to the emitted deleteScheduleEventById
event. Deletes a scheduled event with specified id.
This is largely undocumented at this time, but we are making progress toward figuring it out.
controllerType
- byte that can be passed to EquipmentConfigurationMessage static methods to interpret what type of controller this ishwType
- byte passed to EquipmentConfigurationMessage static methods to determine more info about the hardwareexpansionsCount
- numberversion
- numberpumps
- Pump[]id
- numbertype
- numberpentairType
- PumpTypesname
- stringaddress
- numbercircuits
- PumpCircuit[]primingSpeed
- numberprimingTime
- numberminSpeed
- numbermaxSpeed
- numberspeedStepSize
- numberbackgroundCircuit
- numberfilterSize
- numberturnovers
- numbermanualFilterGPM
- numberminFlow
- numbermaxFlow
- numberflowStepSize
- numbermaxSystemTime
- numbermaxPressureIncrease
- numberbackwashFlow
- numberbackwashTime
- numberrinseTime
- numbervacuumFlow
- numbervacuumTime
- number
heaterConfig
- HeaterConfigbody1SolarPresent
- booleanbody2SolarPresent
- booleanthermaFloCoolPresent
- booleansolarHeatPumpPresent
- booleanthermaFloPresent
- booleanunits
- number
valves
- Valves[]loadCenterIndex
- numbervalveIndex
- numbervalveName
- stringloadCenterName
- stringdeviceId
- numbersCircuit
- string
delays
- DelayspoolPumpOnDuringHeaterCooldown
- booleanspaPumpOnDuringHeaterCooldown
- booleanpumpOffDuringValveAction
- boolean
misc
- MiscintelliChem
- booleanmanualHeat
- boolean
remotes
- SLRemoteDatafourButton
- number[]tenButton
- number[][]quickTouch
- number[]
highSpeedCircuits
- number[]lights
- LightsallOnAllOff
- number[]
spaFlow
- SpaFlowisActive
- booleanpumpId
- numberstepSize
- number
numPumps
- numberrawData
- rawDataversionData
- number[]highSpeedCircuitData
- number[]valveData
- number[]remoteData
- number[]heaterConfigData
- number[]delayData
- number[]macroData
- number[]miscData
- number[]lightData
- number[]pumpData
- number[]sgData
- number[]spaFlowData
- number[]
Passed as an argument to the emitted getChemHistoryData
event. Contains information about the remote unit's pH and ORP readings over time as well as pH and ORP feed on/off times.
phPoints
- array of objects containing the pH reading over time. Each object contains atime
key containing a Javascript Date object, and apH
key containing the pH reading as a float.orpPoints
- array of objects containing the ORP reading over time. Each object contains atime
key containing a Javascript Date object, and anorp
key containing the ORP reading as an integer.phRuns
- array of objects containing the pH feed on/off times. Each object contains anon
key containing a Javascript Date object for when the feed turned on, and anoff
key containing a Javascript Date object for when the feed turned off.orpRuns
- array of objects containing the ORP feed on/off times. Each object contains anon
key containing a Javascript Date object for when the feed turned on, and anoff
key containing a Javascript Date object for when the feed turned off.
Passed as an argument to the emitted setCustomNames
event.
names
- array of strings containing all custom names
Passed as an argument to the emitted gatewayFound
event. Contains information about the remote unit's status and access properties.
Note: these properties are available on the object acquired by calling .get()
on the given message.
gatewayFound
- boolean indicating whether a unit was foundlicenseOK
- boolean indicating if the license is valid (I've never seen this be false)ipAddr
- string containing the ipv4 address to remotely connect to this unitport
- number containing the port to connect to the unitportOpen
- boolean indicating whether or not the port is open and able to be connected torelayOn
- boolean indicating whether the relay is on (unsure what exactly this indicates; it's always been false in my tests)
Passed as an argument to the emitted getHistoryData
event. Contains information about the remote unit's temperature and circuit on/off times over time.
airTemps
- array of objects containing the air temperature over time. Each object contains atime
key containing a Javascript Date object, and atemp
key containing the temperature as an integer.poolTemps
- array of objects containing the pool temperature over time. Each object contains atime
key containing a Javascript Date object, and atemp
key containing the temperature as an integer.poolSetPointTemps
- array of objects containing the pool setpoint over time. Each object contains atime
key containing a Javascript Date object, and atemp
key containing the temperature as an integer.spaTemps
- array of objects containing the spa temperature over time. Each object contains atime
key containing a Javascript Date object, and atemp
key containing the temperature as an integer.spaSetPointTemps
- array of objects containing the spa setpoint over time. Each object contains atime
key containing a Javascript Date object, and atemp
key containing the temperature as an integer.poolRuns
- array of objects containing the pool on/off times over time. Each object contains anon
key containing a Javascript Date object for when the circuit turned on, and anoff
key containing a Javascript Date object for when the circuit turned off.spaRuns
- array of objects containing the spa on/off times over time. Each object contains anon
key containing a Javascript Date object for when the circuit turned on, and anoff
key containing a Javascript Date object for when the circuit turned off.solarRuns
- array of objects containing the solar on/off times over time. Each object contains anon
key containing a Javascript Date object for when the circuit turned on, and anoff
key containing a Javascript Date object for when the circuit turned off.heaterRuns
- array of objects containing the heater on/off times over time. Each object contains anon
key containing a Javascript Date object for when the circuit turned on, and anoff
key containing a Javascript Date object for when the circuit turned off.lightRuns
- array of objects containing the light on/off times over time. Each object contains anon
key containing a Javascript Date object for when the circuit turned on, and anoff
key containing a Javascript Date object for when the circuit turned off.
Passed as an argument to the emitted getPumpStatus
event. Gets information about the specified pump.
pumpId
- id of pump to get information about, first pump is 1
isRunning
- boolean that says if pump is runningpumpType
- 0 if not installed or one of the IntelliFlo constants:- PumpTypes.PUMP_TYPE_INTELLIFLOVF
- PumpTypes.PUMP_TYPE_INTELLIFLOVS
- PumpTypes.PUMP_TYPE_INTELLIFLOVSF
pumpWatts
- current Watts usage of the pumppumpRPMs
- current RPMs of the pumppumpGPMs
- current GPMs of the pumppumpCircuits
- Array of 8 items each containingcircuitId
- Circuit Id (CircuitId matched data returned by EquipmentConfigurationMessage'sgetCircuitByDeviceIdAsync()
)speed
- the set point for this pump/circuit combo (in either RPMs or GPMs depending on the value ofisRPMs
)isRPMs
- boolean indicating if the set point is in RPMs (false means it's in GPMs)
pumpUnknown1
- unknown data; always 0pumpUnknown2
- unknown data; always 255
Passed as an argument to the emitted getScheduleData
event. Retrieves a list of schedule events of the specified type, either 0 for regular events or 1 for one-time events.
data
- array of schedule datumscheduleId
- the associated scheduleIdcircuitId
- the circuit this schedule affectsstartTime
- the start time of the event, specified as a string in 24-hour time, so, for example, 6:00AM would be '0600' (see conversion functions)stopTime
- the stop time of the event, specified as a string in 24-hour time, so, for example, 6:00AM would be '0600' (see conversion functions)dayMask
- 7-bit mask that determines which days the schedule is active for, MSB is always 0, valid numbers 1-127 (see conversion functions)flags
- bit 0 is the schedule type, if 0 then regular event, if 1 its a run-once
- bit 1 indicates whether heat setPoint should be changed
heatCmd
- integer indicating the desired heater mode. Valid values are:- HeatModes.HEAT_MODE_OFF
- HeatModes.HEAT_MODE_SOLAR
- HeatModes.HEAT_MODE_SOLARPREFERRED
- HeatModes.HEAT_MODE_HEATPUMP
- HeatModes.HEAT_MODE_DONTCHANGE
heatSetPoint
- the temperature set point if heat is to be changed (ignored if bit 1 of flags is 0)days
- which days this schedule is active for; this is just thedayMask
property run through decodeDayMask)` for convenience
pumps
- Pump[]id
- numbertype
- numberpentairType
- PumpTypesname
- stringaddress
- numbercircuits
- PumpCircuit[]primingSpeed
- numberprimingTime
- numberminSpeed
- numbermaxSpeed
- numberspeedStepSize
- numberbackgroundCircuit
- numberfilterSize
- numberturnovers
- numbermanualFilterGPM
- numberminFlow
- numbermaxFlow
- numberflowStepSize
- numbermaxSystemTime
- numbermaxPressureIncrease
- numberbackwashFlow
- numberbackwashTime
- numberrinseTime
- numbervacuumFlow
- numbervacuumTime
- number
heaterConfig
- HeaterConfigbody1SolarPresent
- booleanbody2SolarPresent
- booleanthermaFloCoolPresent
- booleansolarHeatPumpPresent
- booleanthermaFloPresent
- booleanunits
- number
valves
- Valves[]loadCenterIndex
- numbervalveIndex
- numbervalveName
- stringloadCenterName
- stringdeviceId
- numbersCircuit
- string
delays
- DelayspoolPumpOnDuringHeaterCooldown
- booleanspaPumpOnDuringHeaterCooldown
- booleanpumpOffDuringValveAction
- boolean
misc
- MiscintelliChem
- booleanmanualHeat
- boolean
remotes
- SLRemoteDatafourButton
- number[]tenButton
- number[][]quickTouch
- number[]
highSpeedCircuits
- number[]lights
- LightsallOnAllOff
- number[]
numPumps
- number
Contains information about the system's current time and date. Passed as a return object/
an argument to the emitted getSystemTimeAsync
event.
date
-Date
instance representing the current system datetime (preferred, the other properties are derived from this one and provided for backward compatibility purposes)year
- short representing current system yearmonth
- short representing current system month (where 1 is January, 2 is February, etc.)dayOfWeek
- short representing current system day of the week (where 1 is Sunday and 7 is Saturday)day
- short representing current system day of the monthhour
- short representing current system hour (24-hour time where 0 is midnight, 13 is 1PM, etc.)minute
- short representing current system minutesecond
- short representing current system secondmillisecond
- short representing current system millisecondadjustForDST
- bool indicating whether the system should adjust for daylight saving time or not
Passed as an argument to sendLightCommandAsync
.
controllerId
- integer indicating the ID of the controller to send this command to.- Note that while
SLControllerConfig
includes a controllerId, this ID, in my experience, should always be 0.
- Note that while
command
- integer indicating which command to send to the lights. Valid values are:- LightCommands.LIGHT_CMD_LIGHTS_OFF
- LightCommands.LIGHT_CMD_LIGHTS_ON
- LightCommands.LIGHT_CMD_COLOR_SET
- LightCommands.LIGHT_CMD_COLOR_SYNC
- LightCommands.LIGHT_CMD_COLOR_SWIM
- LightCommands.LIGHT_CMD_COLOR_MODE_PARTY
- LightCommands.LIGHT_CMD_COLOR_MODE_ROMANCE
- LightCommands.LIGHT_CMD_COLOR_MODE_CARIBBEAN
- LightCommands.LIGHT_CMD_COLOR_MODE_AMERICAN
- LightCommands.LIGHT_CMD_COLOR_MODE_SUNSET
- LightCommands.LIGHT_CMD_COLOR_MODE_ROYAL
- LightCommands.LIGHT_CMD_COLOR_SET_SAVE
- LightCommands.LIGHT_CMD_COLOR_SET_RECALL
- LightCommands.LIGHT_CMD_COLOR_BLUE
- LightCommands.LIGHT_CMD_COLOR_GREEN
- LightCommands.LIGHT_CMD_COLOR_RED
- LightCommands.LIGHT_CMD_COLOR_WHITE
- LightCommands.LIGHT_CMD_COLOR_PURPLE
Passed as an argument to the emitted pong
event handler.
Passed as an argument to the emitted equipmentState
event handler.
Returns a bool indicating whether the device is in a normal operating state.
Returns a bool.
Returns a bool indicating whether the device is in service mode or not.
Returns a bool indicating whether the spa is currently active or not.
Returns a bool indicating whether the pool is currently active or not.
ok
- can be interpreted withisDevice...
methods.freezeMode
- byte representing whether the device is in freeze mode or not.remotes
- bytepoolDelay
- bytespaDelay
- bytecleanerDelay
- byteairTemp
- integer representing the current temperature (check controller config to see if it's in celsius or fahrenheit)currentTemp
- array of size 0-2 indicating current temperature of each body as an integer (pool: 0, spa: 1) (check controller config to see if it's in celsius or fahrenheit)heatStatus
- array of size 0-2 indicating whether heat is active or not for each body as an integer (pool: 0, spa: 1)setPoint
- array of size 0-2 holding the heating set point for each body as an integer (pool: 0, spa: 1) (check controller config to see if it's in celsius or fahrenheit)coolSetPoint
- array of size 0-2 holding the cooling set point for each body as an integer (pool: 0, spa: 1; the spa seems to always track air temperature for this, however) (check controller config to see if it's in celsius or fahrenheit)heatMode
- array of size 0-2 indicating whether heating is enabled or not for each body as an integer (pool: 0, spa: 1)circuitArray
- array holding all circuits in the systemid
- integer representing the circuit's ID (spa is 500, pool is 505)state
- integer indicating whether the circuit is on or not (0/1)colorSet
- bytecolorPos
- bytecolorStagger
- bytedelay
- byte
pH
- float indicating the current pH level (e.g.: 7.62)orp
- integer indicating the current ORP value if available (e.g.: 650)saturation
- float indicating the water balance/saturation level (e.g.: -0.13)saltPPM
- integer indicating the salt level in parts-per-million (e.g.: 3000)pHTank
- integer indicating the fill level of the pH tank (e.g.: 4)orpTank
- integer indicating the fill level of the ORP tankalarms
- integer indicating how many alarms are currently active
Passed as an argument to the emitted removeClient
event.
Passed as an argument to the emitted intellichlorConfig
event handler.
installed
- boolean indicating whether a salt cell is installed or notstatus
- integer bitmaskpoolSetpoint
- integer indicating the output level of the salt cell for the pool. Valid setpoints are 40-104F or 4-40C.spaSetpoint
- integer indicating the output level of the salt cell for the spa. Valid setpoints are 40-104F or 4-40C.salt
- integer indicating salt level in parts-per-millionflags
- integer bitmasksuperChlorTimer
- integer
Passed as an argument to the emitted setCircuitRuntimebyId
event. Configures default run-time of a circuit, usually referred to as the 'egg timer'. This also applies to 'run-once' programs as this will set the length of the program.
circuitId
- id of the circuit to which this event applies torunTime
- integer specifying the run time in minutes
Passed as an argument to the emitted circuitStateChanged
event.
circuitId
- integer indicating the ID of the circuit to set the state of.- This ID can be retrieved from
SLControllerConfigData
'scircuitArray
property.
- This ID can be retrieved from
circuitState
- integer indicating whether to switch the circuit on (1
) or off (0
).
Passed as an argument, returned to the emitted heatModeChanged
event. Valid values depend on installed equipment.
controllerId
- integer indicating the ID of the controller to send this command to.- Note that while
SLControllerConfig
includes a controllerId, this ID, in my experience, should always be 0.
- Note that while
bodyType
- integer indicating the type of body to set the setpoint of. The pool is body0
and the spa is body1
.heatMode
- integer indicating the desired heater mode. Valid values are:- HeatModes.HEAT_MODE_OFF
- HeatModes.HEAT_MODE_SOLAR
- HeatModes.HEAT_MODE_SOLARPREFERRED
- HeatModes.HEAT_MODE_HEATPUMP
- HeatModes.HEAT_MODE_DONTCHANGE
Passed as an argument to the emitted setPointChanged
event. Receives a BoolData object.
Passed as an argument to the emitted setIntellichlorConfig
event.
controllerId
- integer indicating the ID of the controller to send this command to.- Note that while
SLControllerConfig
includes a controllerId, this ID, in my experience, should always be 0.
- Note that while
poolOutput
- integer indicating the output level of the salt cell for the pool. I believe this operates on a 0-100 scale.spaOutput
- integer indicating the output level of the salt cell for the spa. I believe this operates on a 0-100 scale.
Passed as an argument to the emitted setScheduleEventById
event. Configures an event with properties as described below.
scheduleId
- id of a schedule previously created, see scheduleaddNewScheduleEventAsync()`circuitId
- id of the circuit to which this event appliesstartTime
- the start time of the event, specified as minutes since midnight (see conversion functions)- example: 6:00am would be 360
- example: 6:15am would be 375
stopTime
- the stop time of the event, specified as minutes since midnight (see conversion functions)dayMask
- 7-bit mask that determines which days the schedule is active for, MSB is always 0, valid numbers 1-127
flags
- bit 0 is the schedule type, if 0 then regular event, if 1 its a run-once
- bit 1 indicates whether heat setPoint should be changed
heatCmd
- integer indicating the desired heater mode. Valid values are:- HeatModes.HEAT_MODE_OFF
- HeatModes.HEAT_MODE_SOLAR
- HeatModes.HEAT_MODE_SOLARPREFERRED
- HeatModes.HEAT_MODE_HEATPUMP
- HeatModes.HEAT_MODE_DONTCHANGE
heatSetPoint
- the temperature set point if heat is to be changed (ignored if bit 1 of flags is 0)
Passed as an argument to the emitted setSystemTime
event.
Passed as an argument to the emitted version
event handler.
version
- a string representing the system's version
version
- numberzip
- stringlastUpdate
- DatelastRequest
- DatedateText
- stringtext
- stringcurrentTemperature
- numberhumidity
- numberwind
- stringpressure
- numberdewPoint
- numberwindChill
- numbervisibility
- numberdayData
- SLWeatherForecastDayData[]dayTime
- DatehighTemp
- numberlowTemp
- numbertext
- string
sunrise
- numbersunset
- number