Domoticz Mi TempHum Monitor

A library written in Python that connects to Xiaomi via bluetooth and retrieves data on the current temperature, humidity and battery status of the device.

Requirements

  • Linux based device (like Raspberry Pi) with installed Python 3 and Bluetooth Low Energy Support (Raspberry supports this standard by default, if you use a different device, you must check the manufacturer's website; remember that you can always buy an external USB module).
  • Mi Bluetooth Temperature & Humidity Monitor device (the first, oval version)
  • The following python packages installed on device: requests, bluepy

Installation

Get the MAC address of the device

You can do this in several ways:

  • (easiest) use the "BLE Scanner" or similar application on your mobile device,
  • use the hcitool application on your Linux device.

Configure Domoticz

Open the Domoticz panel, expand "Setup", select "Hardware" and add a new device named "Mi TempHum Monitor", type "Dummy (Does nothing, use for virtual switches only)". Leave the rest of the options unchanged and press the "Add" button.

At the newly created item in the "Type" column, press the "Create Virtual Sensors" button. A modal will appear in which you must enter the name of the sensor "Temp & Hum" and the type "Temp + Hum".

Now go to the "Temperature" tab and click the "Edit" button on the newly created item. At the top of the open modal you have the "Idx" field - write down its value somewhere.

Install script

Install required Python packages:

pip3 install requests bluepy

Clone the repository to any directory on your device, e.g. to the home directory.

cd
git clone https://github.com/paulomac1000/Domoticz-MiTempHum-Monitor

Change to the script's directory

cd Domoticz-MiTempHum-Monitor

Configure the script

nano miTempHumStatus.py

Go to line 8 (to the code below) and replace this url with your Domoticz url, or leave the default configuration if the script is run on the same machine.

DOMOTICZ_SERVER = "127.0.0.1:8080"

Go to line 18 (to the code below) and replace the value in square brackets with the MAC address of your device and change the value after the equal sign to Idx of the added sensor in Domoticz. In the following lines, you can add the configuration of other devices in the same way, if you have any.

sensor_dict["00:00:00:00:00:00"] = 99

Close the file with ctrl+x and save changes.

Usage

To run a script, run it from the command line.

python3 miTempHumStatus.py

For the script to run automatically, add it to the crontab.

crontab -e

And call script. The following command will run the script every 15 minutes.

*/15 * * * * python3 /home/pi/Domoticz-MiTempHum-Monitor/miTempHumStatus.py

Contributing

Pull requests are welcome. For major changes, please open an issue first to discuss what you would like to change.

Show your support

Please star this repository if this project helped you!

Thanks

Thanks to fr31b3u73r who made the first version of the script miThermoHygro (in Python 2). His script doesn't work anymore, but based on his work, I fixed bugs and extended its functionality.