dcm2niix will follow the advice of Paul S. Morgan (below) for BEP001 tags. Perhaps @mr-jaemin and @drmclem can provide any advice from a manufacturer perspective or advocate for more details in DICOMS with future software releases. Regarding non-EPI scans, the TR in 0018,0080 appears to be manufacturer specific. Unfortunately, the is no known mechanism to infer both
|
…onfig Closes Gear-665 Metadata & Gear-658 Config ENH: Upgrade dcm2niix algorithm version to latest. The most applicable dcm2niix version upgrade includes fixes for BIDS RepetitionTimeExcitation and RepetitionTimeInversion tags (rordenlab/dcm2niix#439) ENH: Incorporate additional dcm2niix command options including NRRD format, comments, and verbose logging. DOC: Updates to README regarding metadata captured from this Gear.
* tag 'v1.0.20201102': (68 commits) New stable release (v1.0.20201102) Update dcm_qa_nih submodule. Update dcm_qa submodule. Unify GE slice timing Disable to estimate Slice Time for Diffusion and Others Verbose GE slice time GE enhancing software version detection epi/epi2/EPI/EPI2 bug fix Check slices in volume consistent with locations in acquisition (GE: 0021,104F; public: 0054,0081). Detecting missing DICOMs for GE series. GE Detect Group Delay SliceTiming GE multi-phase. detection GE Slice Times Further work on GE slice timing Improve GE Slice Timing Detection RepetitionTimeExcitation (rordenlab#439) Typo Detect if TR and TimeBetweenVolumes differ (UNFmontreal/Dcm2Bids#90) Identify GE Localizers (rordenlab#432) GE enhanced BIDS: report epi/epiRT, through-plane interpolation, round bvec ...
For EPI-based DWI and fMRI scans the DICOM
RepetitionTime
(0018, 0080) is identical to the sampling rate. However, this is not the case for all sequences. Upcoming versions of dcm2niix measure the time between volumes (based onAcquisitionTime
of the first slice in the first and last volume). If this differs between the DICOMRepetitionTime
(0018, 0080), the BIDS tagRepetitionTime
will be used for time between volumes and the tagRepetitionTimePreparation
will store the value of (0018, 0080).The text was updated successfully, but these errors were encountered: