RTI MedTech Reference Architecture

The Medical Reference Architecture demonstrates RTI's best practices for building medical devices using RTI Connext.

This repository contains documentation and demo applications showcasing different capabilities of Connext in a Medical context. The goal is to provide a comprehensive guide to help developers leverage Connext for building robust, scalable, and interoperable medical systems.

Contents

Introduction

RTI Connext is a leading connectivity framework designed to facilitate real-time data distribution in distributed systems. In the medical field, it is crucial to have reliable and timely data exchange between various medical devices and systems. This project aims to illustrate how Connext can be used to build a robust Medical Reference Architecture that ensures data interoperability, scalability, and reliability.

By following the examples and best practices outlined in this documentation, architects and developers can find inspiration to create medical applications.

Getting Started

RTI strongly recommends proceeding in the following order:

  1. Setup: Clone the repository.
  2. Run: Run the demos.
  3. Learn: Understand the architecture.

Cloning the Repository

To clone the repository you will need to run git clone as follows to download both the repository and its submodule dependencies:

git clone --recurse-submodule https://github.com/rticommunity/rticonnextdds-medtech-reference-architecture.git

If you forget to clone the repository with --recurse-submodule, simply run the following command to pull all the dependencies:

git submodule update --init --recursive

For the specific demos and their prerequisites, refer to the README.md located in each demo folder.

Hands-On: Demos

The RTI MedTech Reference Architecture demos showcase usage and capabilities of the provided system architecture.

RTI recommends following along the demo-specific READMEs before returning here and learning more about the designed system architecture.

  • Demo 1 : Digital Operating Room

  • Demo 2 : RTI Recording Service & RTI Replay Service

Hands-On: Architecture

RTI System Designer allows you to graphically design, configure, examine, and share Connext system architectures.

RTI recommends using the provided RTI System Designer project file (RefArch.rtisdproj) to follow along with the next section, Architecture Overview.

  1. Launch RTI System Designer.
    • From RTI Launcher:
      1. Open RTI Launcher.
      2. Navigate to the Tools tab.
      3. Click the System Designer button.
    • From a terminal:
      1. Launch the rtisystemdesigner[.bat] script found in the $NDDSHOME/bin folder. Where $NDDSHOME is the folder where Connext is installed.
  2. Open the Project File.
    1. Select Projects in the toolbar.
    2. Click Open in the dropdown.
    3. In the file browser popup, navigate to system_arch/RefArch.rtisdproj and open.

Please refer to Project Management documentation for more detailed instructions on working with RTI System Designer projects.

Architecture Overview

The Medical Reference Architecture is designed to support various use cases within the medical domain. This reference architecture ensures that data flows seamlessly from devices to applications, enabling real-time monitoring, decision-making, and reporting.

The RTI MedTech Reference Architecture consists of the following key components:

Through RTI XML-Based Application Creation, aspects of all 4 components are expressed in XML statically, separate from application code and choice of language. This allows for the extraction of a common system definition from the application logic and behavior - a must-have for designing integrated systems with multiple development teams.

Please find a diagram of the Digital OR demo below:

diagram

Data Types

DDS is a data-centric communication standard that understands user-defined Data Types. You can define a Data Type, its members, and annotations in IDL, XML, or XSD. Conversion between file formats and type-support code generation for (de)serialization can be done with RTI Code Generator.

This reference architecture defines the following Data Types in Types.xml:

Data Type Intended Use
DeviceStatus Describes a status (e.g. ON, PAUSED) for a unique device
DeviceHeartbeat Asserts that a unique device is alive
MotorControl Commands the direction of motion for an arm motor (e.g. SHOULDER, ELBOW)
DeviceCommand Commands initiating a status (e.g. START, SHUTDOWN) to a unique device
Vitals Describes data representative of a unique patient's collected vital signs

Quality of Service (QoS)

Quality of Service (QoS) in DDS characterizes a system's infrastructure and data flow. In a QoS Profile, you can define a set of QoS policy values for a DDS entity (e.g. DomainParticipant, DataWriter, DataReader).

The heirarchy of components configured in a QoS Profile are as follows:

QoS Profile
├── DomainParticipant QoS
├── Topic QoS
├── Publisher QoS
├── Subscriber QoS
├── DataWriter QoS
└── DataReader QoS

This reference architecture defines the following QoS Profiles in Qos.xml:

Qos Library Qos Profile Intended Use
System DefaultParticipant Common, or base, system configuration (e.g. transport, network interfaces, discovery, thread priorities, etc.)
DataFlow Streaming Periodic data that is published at a high frequency (i.e. frequencies <1 second)
DataFlow Status "Current status"-like data, sent once at the beginning of operation and again only upon change to the status
DataFlow Command Data that represents commands or trigger some action in the system
DataFlow Heartbeat Assert and detect the presense of system devices

Domains & Topics

A Domain represents a data space where data can be shared by means of reading and writing the same Topics, where each Topic has a corresponding Data Type. In a Domain, you can define Topics and associate Data Types.

The heirarchy of the components configured in a Domain are as follows:

Domain → Domain ID
├── Type Name → Data Type
└── Topic → Type Name
 
Legend:
 → references

This reference architecture defines the following Domains in DomainLibrary.xml:

Domain Intended Use
OperationalDataDomain Real-time operational medical device data

Note, this reference architecture defines just a single Domain. As a Connext system design scales over time, additional domains could be defined for monitoring, logging, etc. Those additional domains should not affect the performance of our operational data, and therefore should belong to a different domain.

This reference architecture defines the following Topics in DomainLibrary.xml:

Domain Topic Intended Use
OperationalDataDomain t/MotorControl Command the direction of motion for a motor kind (e.g. SHOULDER, ELBOW)
OperationalDataDomain t/DeviceStatus Status (e.g. ON, PAUSED) for a unique system component
OperationalDataDomain t/DeviceHeartbeat Assert that a unique system component is alive
OperationalDataDomain t/DeviceCommand Command initiating a status (e.g. START, SHUTDOWN) to a unique system component
OperationalDataDomain t/Vitals Data representative of a unique patient's collected vital signs

Note, this reference architecture defines a unique Topic for each Data Type defined. While a Topic may only reference a single Data Type, a multi-purpose Data Type can be associated with multiple Topics. It is a best practice to limit the number of defined Topics, but in doing so, it may be feasible to re-use a Data Type for several Topics.

DomainParticipants & DDS Entities

A DomainParticipant is a discoverable Domain actor. DomainParticipants own DDS entities such as DataWriters and DataReaders.

This is where the entire system architecture is tied together:

  • DomainParticipants are configured to operate on a defined Domain.
  • DomainParticipants are configured to use a defined QoS Profile.
  • DataWriters and DataReaders are contained within a defined DomainParticipant.
  • DataWriters and DataReaders are configured to operate on a defined Topic, which has been associated with a defined Data Type.
  • DataWriters and DataReaders are configured to use a defined QoS Profile.

The heirarchy of DDS entities and components configured in a DomainParticipant are as follows:

DomainParticipant → Domain
├── DomainParticipant QoS → QoS Profile
├── Publisher
|   ├── Publisher QoS → QoS Profile
│   └── DataWriter → Topic
|       └── DataWriter QoS → QoS Profile
└── Subscriber
    ├── Subscriber QoS → QoS Profile
    └── DataReader → Topic
        └── DataReader QoS → QoS Profile
        └── Content Filter
            ├── Expression
            └── Expression Parameters

Legend:
 → references

This reference architecture defines the following DomainParticipants in ParticipantLibrary.xml:

Domain DomainParticipant Subscriptions Publications Intended Use
OperationalDataDomain Arm t/DeviceCommand, t/MotorControl t/DeviceStatus, t/DeviceHeartbeat Operate a robotic surgery arm with 5 motors: Base, Shoulder, Elbow, Wrist, and Hand.
OperationalDataDomain ArmController t/DeviceCommand t/MotorControl, t/DeviceHeartbeat Administer commands to an Arm device to control its motors.
OperationalDataDomain Orchestrator t/DeviceStatus, t/DeviceHeartbeat t/DeviceCommand Administer device-level commands and monitor presense and status of all devices.
OperationalDataDomain PatientSensor t/DeviceCommand t/Vitals, t/DeviceStatus, t/DeviceHeartbeat Stream simulated patient vitals.
OperationalDataDomain PatientMonitor t/DeviceCommand, t/Vitals t/DeviceStatus, t/DeviceHeartbeat Process and display patient vitals.

Note, this reference architecture utilizes one DomainParticipant for each device application. It is a best practice to define one DomainParticipant per application. However, in more complex systems, an application may be required to operate on multiple Domains. This requires defining multiple DomainParticipants for those applications that run in parallel.

Going Further

Want to dig deeper?

Check out the the system_arch folder, where the system architecture artifacts live and are covered in more depth!

Additional References

About

Build robust, scalable, and interoperable medical systems with Connext with the documentation and demo applications in this repository

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published