I own this fan(dmaker.fan.p11) and it seems that siid:2 piid:6, which is named as 'status' is actually fan speed of 1~100.

https://miot-spec.org/miot-spec-v2/instance?type=urn:miot-spec-v2:device:fan:0000A005:dmaker-p11:1
{"iid":6,"type":"urn:miot-spec-v2:property:status:00000007:dmaker-p11:1","description":"Status","format":"uint8","access":["read","notify"],"unit":"none","value-range":[1,100,1]}

Therefore, the fix should be made.

@syssi syssi changed the title fix for fan speed level in dmaker.fan.p11 Fix fan speed property of the dmaker.fan.p11 Nov 5, 2020
@syssi syssi merged commit ef31a92 into rytilahti:master Nov 5, 2020