Expand Up @@ -109,7 +109,7 @@ Both events and alarms get recorded in the EVENT_DB.

2. Current Alarm Table

All events with an action field of *raise* get recorded in a table, by name, "ALARM" in addition to getting recorded in Event History Table ( only events corresponding to an alarm has state ).
All events with an action field of *raise* get recorded in a table, by name, "ALARM" in addition to getting recorded in Event History Table ( only events corresponding to an alarm has action field ).
When an application that raised the alarm clears it ( by sending an event with action *clear* ), the alarm record is removed from ALARM table.
An user acknowledging a particular alarm will NOT remove that alarm record from this table.

Expand Down Expand Up @@ -233,6 +233,7 @@ Application owners need to identify various conditions that would be of interest
| 9 | gNMI subscription | |
| 9.1 | Subscribe to openconfig Event container and Alarm container. All events and alarms published to gNMI subscribed clients. | |
| 10 | Clear all events | |
| 11 | Any change in open source should be aligned and upstream. | |

## 1.2 Design Overview

Expand Down Expand Up @@ -297,7 +298,7 @@ Developers of new events or alarms need to update this file by declaring name an

```
{
"__README__": "This is default map of events that eventd reads on bootup and uses while events are raised. Developer can modify this file and send SIGINT to eventd during run-time to read and use the updated file. Alternatively developer can test the new event by adding it to a custom event profile and use 'event profile <filename>' command. This apples that profile without a eventd restart. Developer need to commit default.json file with the new event after testing it out. Supported severities are: 'critical', 'major', 'minor', 'warning' and 'informational'. Supported enable flag values are: 'true' and 'false'.",
"__README__": "This is default map of events that eventd reads on bootup and uses while events are raised. Developer can modify this file and send SIGINT to eventd during run-time to read and use the updated file. Alternatively developer can test the new event by adding it to a custom event profile and use 'event profile <filename>' command. This apples that profile without a eventd restart. Developer need to commit default.json file with the new event after testing it out. Supported severities are: 'critical', 'major', 'minor', 'warning' and 'informational'. Supported enable flag values are: 'true' and 'false'.",
"events": [
{
Expand Down Expand Up @@ -418,10 +419,10 @@ The counter in ALARM_STATS corresponding to the severity of the incoming alarm i
Eventd maintains a lookup map of sequence-id and pair of event-id and source fields.
An entry for the newly received event with action raise is added to this look up map.

. If the action is CLEAR_ALARM, it removes the previous raised record of the alarm using above lookup map.
- If the action is CLEAR_ALARM, it removes the previous raised record of the alarm using above lookup map.
The counter in ALARM_STATS corresponding to the severity of the updated alarm is reduced by 1.

. If the action is ACK_ALARM, alarm consumer finds the raised record of the alarm in the ALARM table using the above lookup map and updates *is_acknowledged* flag to true.
- If the action is ACK_ALARM, alarm consumer finds the raised record of the alarm in the ALARM table using the above lookup map and updates *is_acknowledged* flag to true.
ALARM_STATS is updated by reducing the corresponding severity counter by 1.

pmon can use ALARM_STATS to update system LED based on severities of outstanding alarms:
Expand All @@ -430,7 +431,8 @@ pmon can use ALARM_STATS to update system LED based on severities of outstanding
```
An outstanding alarm is an alarm that is either not cleared or not acknowledged by the user yet.

The following illustrates how ALARM table is updated as alarms goes through their life cycle and how pmon can use ALARM_STATS table to control system LED.
The following illustrates how ALARM table is updated as alarms goes through their life cycle and how can an application use it.
Example here is pmon using ALARM_STATS table to control system LED.

| ALARM | SEVERITY | IS_ACK |
|:-----:|:----------:|:-------:|
Expand Down

0 comments on commit 52fd540

Please sign in to comment.