[Arista] update sensors.conf to ignore sensors (#12529)
Browse files Browse the repository at this point in the history
Why I did it
The sensors and sensord processes were reporting data on unused sensors.
This lead to ALARM messages or erroneous values that could be misinterpreted.

How I did it
Ignore the affected sensors in the sensors.conf

How to verify it
Check that there are no longer ALARM messages from sensord in the syslog or in the output of sensors
  • Loading branch information
Staphylo authored and mssonicbld committed Feb 21, 2023
1 parent ccfb13a commit 3c3a4ac
Show file tree
Hide file tree
Showing 3 changed files with 27 additions and 0 deletions.
9 changes: 9 additions & 0 deletions device/arista/x86_64-arista_7050_qx32s/sensors.conf
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,9 @@ bus "i2c-7" "SCD 0000:02:00.0 SMBus master 0 bus 5"
chip "k10temp-pci-00c3"
label temp1 "Cpu temp sensor"

chip "fam15h_power-pci-00c4"
ignore power1

chip "max6658-i2c-2-4c"
label temp1 "Board temp sensor"
set temp1_max 55
Expand All @@ -34,7 +37,13 @@ chip "pmbus-i2c-6-58"
label temp2 "Power supply 1 inlet temp sensor"
label temp3 "Power supply 1 sensor"

ignore fan2
ignore fan3

chip "pmbus-i2c-5-58"
label temp1 "Power supply 2 hotspot sensor"
label temp2 "Power supply 2 inlet temp sensor"
label temp3 "Power supply 2 sensor"

ignore fan2
ignore fan3
9 changes: 9 additions & 0 deletions device/arista/x86_64-arista_7050cx3_32s/sensors.conf
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,9 @@ bus "i2c-14" "SCD 0000:02:00.0 SMBus master 1 bus 4"
chip "k10temp-pci-00c3"
label temp1 "Cpu temp sensor"

chip "fam15h_power-pci-00c4"
ignore power1

chip "max6658-i2c-2-4c"
label temp1 "Cpu board temp sensor"
set temp1_max 75
Expand All @@ -33,7 +36,13 @@ chip "pmbus-i2c-13-58"
label temp2 "Power supply 1 inlet temp sensor"
label temp3 "Power supply 1 sensor"

ignore fan2
ignore fan3

chip "pmbus-i2c-14-58"
label temp1 "Power supply 2 hotspot sensor"
label temp2 "Power supply 2 inlet temp sensor"
label temp3 "Power supply 2 sensor"

ignore fan2
ignore fan3
9 changes: 9 additions & 0 deletions device/arista/x86_64-arista_7060_cx32s/sensors.conf
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,9 @@ bus "i2c-7" "SCD 0000:02:00.0 SMBus master 0 bus 5"
chip "k10temp-pci-00c3"
label temp1 "Cpu temp sensor"

chip "fam15h_power-pci-00c4"
ignore power1

chip "max6697-i2c-2-1a"
label temp1 "Board sensor"
set temp1_max 95
Expand Down Expand Up @@ -45,7 +48,13 @@ chip "pmbus-i2c-6-58"
label temp2 "Power supply 1 inlet temp sensor"
label temp3 "Power supply 1 exhaust temp sensor"

ignore fan2
ignore fan3

chip "pmbus-i2c-5-58"
label temp1 "Power supply 2 hotspot sensor"
label temp2 "Power supply 2 inlet temp sensor"
label temp3 "Power supply 2 exhaust temp sensor"

ignore fan2
ignore fan3

0 comments on commit 3c3a4ac