Broadcom requires that programmability_ucode_relative_path is set in SAI11.
This soc property replaces the legacy custom_feature_ucode_path
Without this we get the following error:
syncd#supervisord: syncd 0:dbx_file_get_db_location: DB Resource not defined#015
syncd#supervisord: syncd #15#015
syncd#supervisord: syncd 0:dnx_init_pemla_get_ucode_filepath: Error 'Invalid parameter' indicated ; #15#015