Skip to content

Commit

Permalink
Merge branch 'master' into master
Browse files Browse the repository at this point in the history
  • Loading branch information
AnoopKamath authored Aug 10, 2023
2 parents 7d45bff + ab70e66 commit 9aea964
Show file tree
Hide file tree
Showing 2 changed files with 135 additions and 1 deletion.
20 changes: 19 additions & 1 deletion sonic_platform_base/sonic_ssd/ssd_generic.py
Original file line number Diff line number Diff line change
Expand Up @@ -23,6 +23,8 @@
# Set Vendor Specific IDs
INNODISK_HEALTH_ID = 169
INNODISK_TEMPERATURE_ID = 194
SWISSBIT_HEALTH_ID = 248
SWISSBIT_TEMPERATURE_ID = 194

class SsdUtil(SsdBase):
"""
Expand All @@ -42,7 +44,8 @@ def __init__(self, diskdev):
"InnoDisk" : { "utility" : INNODISK, "parser" : self.parse_innodisk_info },
"M.2" : { "utility" : INNODISK, "parser" : self.parse_innodisk_info },
"StorFly" : { "utility" : VIRTIUM, "parser" : self.parse_virtium_info },
"Virtium" : { "utility" : VIRTIUM, "parser" : self.parse_virtium_info }
"Virtium" : { "utility" : VIRTIUM, "parser" : self.parse_virtium_info },
"Swissbit" : { "utility" : SMARTCTL, "parser" : self.parse_swissbit_info },
}

self.dev = diskdev
Expand Down Expand Up @@ -78,6 +81,8 @@ def _parse_vendor(self):
return model_short
elif self.model.startswith('VSF'):
return 'Virtium'
elif self.model.startswith('SFS'):
return 'Swissbit'
else:
return None

Expand Down Expand Up @@ -154,6 +159,19 @@ def parse_virtium_info(self):
except ValueError:
pass

def parse_swissbit_info(self):
if self.ssd_info:
health_raw = self.parse_id_number(SWISSBIT_HEALTH_ID)
if health_raw == NOT_AVAILABLE:
self.health = NOT_AVAILABLE
else:
self.health = health_raw.split()[-1]
temp_raw = self.parse_id_number(SWISSBIT_TEMPERATURE_ID)
if temp_raw == NOT_AVAILABLE:
self.temperature = NOT_AVAILABLE
else:
self.temperature = temp_raw.split()[-3]

def fetch_vendor_ssd_info(self, diskdev, model):
self.vendor_ssd_info = self._execute_shell(self.vendor_ssd_utility[model]["utility"].format(diskdev))

Expand Down
116 changes: 116 additions & 0 deletions tests/ssd_generic_test.py
Original file line number Diff line number Diff line change
Expand Up @@ -532,6 +532,112 @@
ID Attribute High Raw Low Raw Value Worst Threshold
"""

output_swissbit_vendor = """
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-23-2-amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SFSA160GM2AK2TO-I-8C-22K-STD
Serial Number: 00006022750795000010
Firmware Version: SBR15004
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 (minor revision not indicated)
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Aug 2 08:24:31 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 15) minutes.
SCT capabilities: (0x0031) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 000 Pre-fail Always - 0
5 Reallocated_Sector_Ct 0x0013 100 100 000 Pre-fail Always - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 825
12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 447
16 Unknown_Attribute 0x0112 100 100 001 Old_age Always - 4
17 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 30000
160 Unknown_Attribute 0x0002 100 100 000 Old_age Always - 0
161 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 15401195
163 Unknown_Attribute 0x0003 100 100 000 Pre-fail Always - 33
164 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 6506
165 Unknown_Attribute 0x0002 100 100 000 Old_age Always - 38
166 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 1
167 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 4
168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 30000
169 Unknown_Attribute 0x0003 100 100 000 Pre-fail Always - 421
193 Unknown_SSD_Attribute 0x0012 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0023 100 100 000 Pre-fail Always - 25 (Min/Max 22/45)
195 Hardware_ECC_Recovered 0x0012 100 100 000 Old_age Always - 0
196 Reallocated_Event_Count 0x0012 000 000 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0012 100 100 000 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x000b 100 100 000 Pre-fail Always - 0
215 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 4275
231 Unknown_SSD_Attribute 0x1913 100 100 025 Pre-fail Always - 100
235 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 1302467136
237 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0
241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 1186450104
242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 2257141451
243 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0
244 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0
248 Unknown_Attribute 0x0112 100 100 001 Old_age Always - 100
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
"""

class TestSsdGeneric:
@mock.patch('sonic_platform_base.sonic_ssd.ssd_generic.SsdUtil._execute_shell', mock.MagicMock(return_value=output_nvme_ssd))
def test_nvme_ssd(self):
Expand Down Expand Up @@ -631,3 +737,13 @@ def test_virtium_ssd(self, mock_exec):
mock_exec.side_effect = [output_virtium_generic, output_virtium_invalid_remain_life]
virtium_ssd = SsdUtil('/dev/sda')
assert virtium_ssd.get_health() == "N/A"

@mock.patch('sonic_platform_base.sonic_ssd.ssd_generic.SsdUtil._execute_shell')
def test_swissbit_ssd(self, mock_exec):
mock_exec.return_value = output_swissbit_vendor
swissbit_ssd = SsdUtil('/dev/sda')
assert swissbit_ssd.get_health() == '100'
assert swissbit_ssd.get_model() == 'SFSA160GM2AK2TO-I-8C-22K-STD'
assert swissbit_ssd.get_firmware() == "SBR15004"
assert swissbit_ssd.get_temperature() == '25'
assert swissbit_ssd.get_serial() == "00006022750795000010"

0 comments on commit 9aea964

Please sign in to comment.