Publisher: Splunk
Connector Version: 2.2.2
Product Vendor: Microsoft
Product Name: SCOM
Product Version Supported (regex): ".*"
Minimum Product Version: 6.1.1
This app integrates with Microsoft System Center Operations Manager (SCOM) to execute investigative actions
Windows Remote Management(WinRM) should be enabled on the MS SCOM Server for the app to run commands remotely. To allow HTTP communication, WinRM config parameter AllowUnencrypted should be changed to true on SCOM server.
By default WinRM HTTP uses port 80. On Windows 7 and higher the default port is 5985.
By default WinRM HTTPS uses port 443. On Windows 7 and higher the default port is 5986.
This app uses NTLM authorization. The use of the HTTP_PROXY and HTTPS_PROXY environment variables is currently unsupported.
The below configuration variables are required for this Connector to operate. These variables are specified when configuring a SCOM asset in SOAR.
VARIABLE | REQUIRED | TYPE | DESCRIPTION |
---|---|---|---|
server_url | required | string | Server URL |
verify_server_cert | optional | boolean | Verify server certificate |
username | required | string | Username |
password | required | password | Password |
test connectivity - Validate the asset configuration for connectivity using supplied configuration
list endpoints - List all the endpoints/sensors configured on the device
list alerts - List all active alerts
get device info - Get information about device
Validate the asset configuration for connectivity using supplied configuration
Type: test
Read only: True
No parameters are required for this action
No Output
List all the endpoints/sensors configured on the device
Type: investigate
Read only: True
PARAMETER | REQUIRED | DESCRIPTION | TYPE | CONTAINS |
---|---|---|---|---|
domain | optional | Domain | string | domain |
DATA PATH | TYPE | CONTAINS | EXAMPLE VALUES |
---|---|---|---|
action_result.status | string | success failed | |
action_result.parameter.domain | string | domain |
test.local |
action_result.data.*.ActionAccountIdentity | string | SYSTEM | |
action_result.data.*.AuthenticationName | string | ||
action_result.data.*.CommunicationPort | string | port |
5723 |
action_result.data.*.ComputerName | string | host name |
SCCMADMIN |
action_result.data.*.CreateListener | string | False | |
action_result.data.*.DisplayName | string | SCCMADMIN.test.local | |
action_result.data.*.Domain | string | domain |
test.local |
action_result.data.*.HealthState | string | Success | |
action_result.data.*.HeartbeatInterval | string | 60 | |
action_result.data.*.HostComputer | string | SCCMADMIN.test.local | |
action_result.data.*.HostedHealthService | string | SCCMADMIN.test.local | |
action_result.data.*.IPAddress | string | ip ipv6 |
10.0.1.97, fe80::c12e:6326:d283:12c7, fdfe:9042:c53d:0:c12e:6326:d283:12c7, fda7:e6ee:2e09:0:c12e:6326:d283:12c7 |
action_result.data.*.Id | string | c4cbd5e4-7379-302d-e4ee-3af1548b5196 | |
action_result.data.*.InstallTime | string | 08-09-2017 05:47:56 | |
action_result.data.*.InstalledBy | string | user name |
SCOMSERVER\Administrator |
action_result.data.*.LastModified | string | 08-09-2017 06:08:33 | |
action_result.data.*.ManagementGroup | string | SCOM2016_DEMO | |
action_result.data.*.ManagementGroupId | string | 00000000-0000-0000-0000-000000000000 | |
action_result.data.*.ManuallyInstalled | string | False | |
action_result.data.*.MaximumQueueSizeBytes | string | 104857600 | |
action_result.data.*.MaximumSizeOfAllTransferredFilesBytes | string | 0 | |
action_result.data.*.Name | string | host name |
SCCMADMIN.test.local |
action_result.data.*.NetworkName | string | SCCMADMIN.test.local | |
action_result.data.*.PatchList | string | ||
action_result.data.*.PrimaryManagementServerName | string | host name |
SCOMSERVER.test.local |
action_result.data.*.PrincipalName | string | SCCMADMIN.test.local | |
action_result.data.*.ProxyingEnabled | string | False | |
action_result.data.*.RequestCompression | string | True | |
action_result.data.*.Version | string | 8.0.10918.0 | |
action_result.summary.total_endpoints | numeric | 2 | |
action_result.message | string | Total endpoints: 1 | |
summary.total_objects | numeric | 1 | |
summary.total_objects_successful | numeric | 1 |
List all active alerts
Type: investigate
Read only: True
PARAMETER | REQUIRED | DESCRIPTION | TYPE | CONTAINS |
---|---|---|---|---|
computer_name | optional | Computer Name (Primary Management Server Name of endpoint) | string | host name |
DATA PATH | TYPE | CONTAINS | EXAMPLE VALUES |
---|---|---|---|
action_result.status | string | success failed | |
action_result.parameter.computer_name | string | host name |
admin-PC |
action_result.data.*.Category | string | Alert | |
action_result.data.*.ClassId | string | ab4c891f-3359-3fb6-0704-075fbfe36710 | |
action_result.data.*.ConnectorId | string | ||
action_result.data.*.ConnectorStatus | string | NotMarkedForForwarding | |
action_result.data.*.Context | string | ||
action_result.data.*.CustomField1 | string | ||
action_result.data.*.CustomField10 | string | ||
action_result.data.*.CustomField2 | string | ||
action_result.data.*.CustomField3 | string | ||
action_result.data.*.CustomField4 | string | ||
action_result.data.*.CustomField5 | string | ||
action_result.data.*.CustomField6 | string | ||
action_result.data.*.CustomField7 | string | ||
action_result.data.*.CustomField8 | string | ||
action_result.data.*.CustomField9 | string | ||
action_result.data.*.Description | string | ||
action_result.data.*.Id | string | 2f9f3e76-c97f-41e0-950d-0aeb0638273f | |
action_result.data.*.IsMonitorAlert | string | False | |
action_result.data.*.LastModified | string | 14-09-2017 23:23:24 | |
action_result.data.*.LastModifiedBy | string | System | |
action_result.data.*.LastModifiedByNonConnector | string | 14-09-2017 23:23:24 | |
action_result.data.*.MaintenanceModeLastModified | string | 01-01-1900 00:00:00 | |
action_result.data.*.ManagementGroup | string | SCOM2016_DEMO | |
action_result.data.*.ManagementGroupId | string | e0f523c8-8a5c-b1ea-acf8-053104e7ecec | |
action_result.data.*.MonitoringClassId | string | ab4c891f-3359-3fb6-0704-075fbfe36710 | |
action_result.data.*.MonitoringObjectDisplayName | string | SCOMSERVER.test.local | |
action_result.data.*.MonitoringObjectFullName | string | Microsoft.SystemCenter.HealthService:SCOMSERVER.test.local | |
action_result.data.*.MonitoringObjectHealthState | string | Error | |
action_result.data.*.MonitoringObjectId | string | 431cb08b-a738-02db-0732-236a3264d324 | |
action_result.data.*.MonitoringObjectInMaintenanceMode | string | False | |
action_result.data.*.MonitoringObjectName | string | ||
action_result.data.*.MonitoringObjectPath | string | SCOMSERVER.test.local | |
action_result.data.*.MonitoringRuleId | string | c4108e23-e5b9-b0cd-9b75-be85d2039035 | |
action_result.data.*.Name | string | Power Shell Script failed to run | |
action_result.data.*.NetbiosComputerName | string | host name |
SCOMSERVER |
action_result.data.*.NetbiosDomainName | string | domain |
test.local |
action_result.data.*.Owner | string | ||
action_result.data.*.Parameters | string | 19 | |
action_result.data.*.PrincipalName | string | SCOMSERVER.test.local | |
action_result.data.*.Priority | string | Normal | |
action_result.data.*.ProblemId | string | 09deffed-41eb-a1ef-376a-b94c0ea1c4b4 | |
action_result.data.*.RepeatCount | string | 19 | |
action_result.data.*.ResolutionState | string | 0 | |
action_result.data.*.ResolvedBy | string | ||
action_result.data.*.RuleId | string | c4108e23-e5b9-b0cd-9b75-be85d2039035 | |
action_result.data.*.Severity | string | Warning | |
action_result.data.*.SiteName | string | ||
action_result.data.*.StateLastModified | string | 14-09-2017 17:52:43 | |
action_result.data.*.TfsWorkItemId | string | ||
action_result.data.*.TfsWorkItemOwner | string | ||
action_result.data.*.TicketId | string | ||
action_result.data.*.TimeAdded | string | 30-08-2017 23:47:01 | |
action_result.data.*.TimeRaised | string | 30-08-2017 23:47:01 | |
action_result.data.*.TimeResolutionStateLastModified | string | 30-08-2017 23:47:01 | |
action_result.data.*.TimeResolved | string | ||
action_result.data.*.UnformattedDescription | string | ||
action_result.summary.total_alerts | numeric | 1 | |
action_result.message | string | Total alerts: 1 | |
summary.total_objects | numeric | 1 | |
summary.total_objects_successful | numeric | 1 |
Get information about device
Type: investigate
Read only: True
Either ip or computer_name needs to be specified. If ip is provided computer_name is ignored.
PARAMETER | REQUIRED | DESCRIPTION | TYPE | CONTAINS |
---|---|---|---|---|
ip | optional | IP address | string | ip ipv6 |
computer_name | optional | Computer name | string | host name |
DATA PATH | TYPE | CONTAINS | EXAMPLE VALUES |
---|---|---|---|
action_result.status | string | success failed | |
action_result.parameter.computer_name | string | host name |
admin-PC |
action_result.parameter.ip | string | ip ipv6 |
1.2.3.4 |
action_result.data.*.ActionAccountIdentity | string | SYSTEM | |
action_result.data.*.AuthenticationName | string | ||
action_result.data.*.CommunicationPort | string | port |
5723 |
action_result.data.*.ComputerName | string | host name |
SCCMADMIN |
action_result.data.*.CreateListener | string | False | |
action_result.data.*.DisplayName | string | SCCMADMIN.test.local | |
action_result.data.*.Domain | string | domain |
test.local |
action_result.data.*.HealthState | string | Success | |
action_result.data.*.HeartbeatInterval | string | 60 | |
action_result.data.*.HostComputer | string | SCCMADMIN.test.local | |
action_result.data.*.HostedHealthService | string | SCCMADMIN.test.local | |
action_result.data.*.IPAddress | string | ip ipv6 |
10.0.1.97, fe80::c12e:6326:d283:12c7, fdfe:9042:c53d:0:c12e:6326:d283:12c7, fda7:e6ee:2e09:0:c12e:6326:d283:12c7 |
action_result.data.*.Id | string | c4cbd5e4-7379-302d-e4ee-3af1548b5196 | |
action_result.data.*.InstallTime | string | 08-09-2017 05:47:56 | |
action_result.data.*.InstalledBy | string | user name |
SCOMSERVER\Administrator |
action_result.data.*.LastModified | string | 08-09-2017 06:08:33 | |
action_result.data.*.ManagementGroup | string | SCOM2016_DEMO | |
action_result.data.*.ManagementGroupId | string | 00000000-0000-0000-0000-000000000000 | |
action_result.data.*.ManuallyInstalled | string | False | |
action_result.data.*.MaximumQueueSizeBytes | string | 104857600 | |
action_result.data.*.MaximumSizeOfAllTransferredFilesBytes | string | 0 | |
action_result.data.*.Name | string | host name |
SCCMADMIN.test.local |
action_result.data.*.NetworkName | string | SCCMADMIN.test.local | |
action_result.data.*.PatchList | string | ||
action_result.data.*.PrimaryManagementServerName | string | host name |
SCOMSERVER.test.local |
action_result.data.*.PrincipalName | string | SCCMADMIN.test.local | |
action_result.data.*.ProxyingEnabled | string | False | |
action_result.data.*.RequestCompression | string | True | |
action_result.data.*.Version | string | 8.0.10918.0 | |
action_result.summary | string | ||
action_result.message | string | Device found | |
summary.total_objects | numeric | 1 | |
summary.total_objects_successful | numeric | 1 |