Expand Up @@ -1178,46 +1178,47 @@ A few values I wasn't able to figure out, but the most relevant are there. If yo

??? summary "View script"
```
>D
>B
spinm(4 1)
=>sensor53 r
>M 1
+1,3,s,0,9600,sml
1,77070100010800FF@1000,Bezug (180),kWh,zaehlerstand_180,3
;1,77070100010801FF@1,Tarif 1 (180),Wh,zaehlerstand_tarif_1_180,3
;1,77070100010802FF@1,Tarif 2 (180),Wh,zaehlerstand_tarif_2_180,3
1,77070100020800FF@1000,Einspeisung (280),kWh,zaehlerstand_280,3
;1,77070100020801FF@1,Tarif 1 (280),Wh,zaehlerstand_tarif_1_280,3
;1,77070100020802FF@1,Tarif 2 (280),Wh,zaehlerstand_tarif_2_280,3
1,770701000E0700FF@1,Netz Frequenz,Hz,netz_frequenz,1
1,77070100100700FF@1,aktuelle Wirkleistung,W,aktuelle_wirkleistung,0
1,770701001F0700FF@1,Strom L1,A,strom_l1,2
1,77070100200700FF@1,Spannung L1,V,spannung_l1,1
1,77070100240700FF@1,Wirkleistung L1,W,wirkleistung_l1,0
1,77070100330700FF@1,Strom L2,A,strom_l2,2
1,77070100340700FF@1,Spannung L2,V,spannung_l2,1
1,77070100380700FF@1,Wirkleistung L2,W,wirkleistung_l2,0
1,77070100470700FF@1,Strom L3,A,strom_l3,2
1,77070100480700FF@1,Spannung L3,V,spannung_l3,1
1,770701004C0700FF@1,Wirkleistung L3,W,wirkleistung_l3,0
1,77070100510701FF@1,Phasenwinkel U L1/L2,°,phasenwinkel_u_l1_l2,0
1,77070100510702FF@1,Phasenwinkel U L1/L3,°,phasenwinkel_u_l1_l3,0
1,77070100510704FF@1,Phasenwinkel I/U L1,°,phasenwinkel_i_u_l1,0
1,7707010051070FFF@1,Phasenwinkel I/U L2,°,phasenwinkel_i_u_l2,0
1,7707010051071AFF@1,Phasenwinkel I/U L3,°,phasenwinkel_i_u_l3,0
;1,77070100600100FF@#,Seriennummer,,seriennummer,0
;1,7707010060320101@#,Hersteller,,hersteller,0
;1,7707010060320104@#,HW Version,,hw_version,0
;1,7707010060320204@#,HW Version PCB2,,hw_version,0
;1,7707010060320404@#,Parameter Version,,parameter_version,0
;1,77070100605A0201@#,FW Checksum,,fw_checksum,0
;1,77070100605A0202@#,Unbekannt 2,,unbekanntes_mqtt_topic_2,0
;1,7707010000020000@#,Firmware Version,,firmwareversion,0
;1,7707010000020001@#,Unbekannt 1,,unbekanntes_mqtt_topic_1,0

```

>D
>B
spinm(4 1)
=>sensor53 r
>M 1
+1,3,s,0,9600,sml
1,77070100010800FF@1000,Bezug (180),kWh,zaehlerstand_180,3
;1,77070100010801FF@1,Tarif 1 (180),Wh,zaehlerstand_tarif_1_180,3
;1,77070100010802FF@1,Tarif 2 (180),Wh,zaehlerstand_tarif_2_180,3
1,77070100020800FF@1000,Einspeisung (280),kWh,zaehlerstand_280,3
;1,77070100020801FF@1,Tarif 1 (280),Wh,zaehlerstand_tarif_1_280,3
;1,77070100020802FF@1,Tarif 2 (280),Wh,zaehlerstand_tarif_2_280,3
1,770701000E0700FF@1,Netz Frequenz,Hz,netz_frequenz,1
1,77070100100700FF@1,aktuelle Wirkleistung,W,aktuelle_wirkleistung,0
1,770701001F0700FF@1,Strom L1,A,strom_l1,2
1,77070100200700FF@1,Spannung L1,V,spannung_l1,1
1,77070100240700FF@1,Wirkleistung L1,W,wirkleistung_l1,0
1,77070100330700FF@1,Strom L2,A,strom_l2,2
1,77070100340700FF@1,Spannung L2,V,spannung_l2,1
1,77070100380700FF@1,Wirkleistung L2,W,wirkleistung_l2,0
1,77070100470700FF@1,Strom L3,A,strom_l3,2
1,77070100480700FF@1,Spannung L3,V,spannung_l3,1
1,770701004C0700FF@1,Wirkleistung L3,W,wirkleistung_l3,0
1,77070100510701FF@1,Phasenwinkel U L1/L2,°,phasenwinkel_u_l1_l2,0
1,77070100510702FF@1,Phasenwinkel U L1/L3,°,phasenwinkel_u_l1_l3,0
1,77070100510704FF@1,Phasenwinkel I/U L1,°,phasenwinkel_i_u_l1,0
1,7707010051070FFF@1,Phasenwinkel I/U L2,°,phasenwinkel_i_u_l2,0
1,7707010051071AFF@1,Phasenwinkel I/U L3,°,phasenwinkel_i_u_l3,0
;1,77070100600100FF@#,Seriennummer,,seriennummer,0
;1,7707010060320101@#,Hersteller,,hersteller,0
;1,7707010060320104@#,HW Version,,hw_version,0
;1,7707010060320204@#,HW Version PCB2,,hw_version,0
;1,7707010060320404@#,Parameter Version,,parameter_version,0
;1,77070100605A0201@#,FW Checksum,,fw_checksum,0
;1,77070100605A0202@#,Unbekannt 2,,unbekanntes_mqtt_topic_2,0
;1,7707010000020000@#,Firmware Version,,firmwareversion,0
;1,7707010000020001@#,Unbekannt 1,,unbekanntes_mqtt_topic_1,0
#
```

### Elster / Honeywell AS1440 (OBIS)

Based on Landis script with changed timings in the >F section, as AS1440 seems to be slower in responding.
Expand All @@ -1227,6 +1228,7 @@ Current power values get published to mqtt immediately when received from the me

??? summary "View script"
```

>D
scnt=0
res=0