45 changes: 37 additions & 8 deletions docs/Smart-Meter-Interface.md
Original file line number Diff line number Diff line change
Expand Up @@ -577,7 +577,7 @@ After unlocking the meter, you can run the following script
#
```

### Carlo Gavazzi EM340 (MODBUS RTU)
### Carlo Gavazzi EM340 (MODBus RTU)

??? summary "View script"
```
Expand Down Expand Up @@ -1602,9 +1602,11 @@ by the supplier. Therefore it is set to a fixed baud rate of 300 and can not be
#
```

### Fronius Symo 10.0-3-M (MODBUS)
### Fronius Symo 10.0-3-M (MODBus TCP)

Fronius inverter, using Modbus TCP feature
Fronius inverter, using Modbus TCP feature.

For this script the inverter must be configured to use Sunspec Model Type "int+SF"

??? summary "View script"
```
Expand Down Expand Up @@ -1649,6 +1651,33 @@ Fronius inverter, using Modbus TCP feature
#
```

Use this script when the inverter is configured to use Sunspec Model Type "float":

??? summary "View script"
```
>D
>B
->sensor53 r

>M 1
+1,[192.168.2.251],m,0,502,FRONIUS,0,100,r01039C870020
1,=so3,80
1,010340ffffffff@i0:1,AC Current,A,11_7_0,3
1,010340x4ffffffff@i0:1,L1 Current,A,31_7_0,3
1,010340x8ffffffff@i0:1,L2 Current,A,51_7_0,3
1,010340x12ffffffff@i0:1,L3 Current,A,71_7_0,3
1,010340x28ffffffff@i0:1,L1 Voltage,V,32_7_0,2
1,010340x32ffffffff@i0:1,L2 Voltage,V,52_7_0,2
1,010340x36ffffffff@i0:1,L3 Voltage,V,72_7_0,2
1,010340x40ffffffff@i0:1000,Output Power,kW,2_7_0,3
1,010340x44ffffffff@i0:1,Frequency,Hz,14_7_0,3
1,010340x48ffffffff@i0:1000,Apparent Power,kVA,9_7_0,3
1,010340x52ffffffff@i0:1000,Reactive Power,kVAr,4_7_0,3
1,010340x56ffffffff@i0:1,Power Factor,,13_7_0,3
1,010340x60ffffffff@i0:1000,AC Lifetime En,kWh,2_8_0,3
#
```

### Growatt MAX4200 (MODBus)

Growatt solar inverter. this example also shows how to send cmds to modbus
Expand Down Expand Up @@ -1912,7 +1941,7 @@ After unlocking the meter, you can run the following script
#
```

### Huawei SUN2000-10KTL (Modbus)
### Huawei SUN2000-10KTL (MODBus)

For writing 32-bit registers like 40126, use [ModBus Bridge](Modbus-Bridge) driver and send two 16-bit numbers. i.e. `modbussend {"deviceaddress": 1, "functioncode": 16, "startaddress":40126, "type":"int16", "count":2, "values":["0","6666"]}`

Expand Down Expand Up @@ -1945,7 +1974,7 @@ For writing 32-bit registers like 40126, use [ModBus Bridge](Modbus-Bridge) driv
#
```

### inepro PRO380-Mod (Modbus)
### inepro PRO380-Mod (MODBus)

??? summary "View script"
```
Expand Down Expand Up @@ -2895,7 +2924,7 @@ Documentation for this Counter is very small. This informations were collected a
15:48:53.542 : 0.2.2(:::::G11)!
```

### Peacefair PZEM004TV30 (MODBUS)
### Peacefair PZEM004TV30 (MODBus)

PZEM004T V30 multiple meters on Modbus

Expand Down Expand Up @@ -3188,7 +3217,7 @@ This meter sends bursts of data at 115200 baud every 10 seconds. Some data lines
#
```

### Schneider iEM3150 (Modbus)
### Schneider iEM3150 (MODBus)
Set device parity to EVEN. Set device serial baud rate to 9600.

??? summary "View script"
Expand Down Expand Up @@ -3566,7 +3595,7 @@ Tested on an AEConversion INV500-90 with RS485 interface.
1,212717x4UUuux4@1000,Energie,kWh,energy_sun,3
#
```
### SMA Solar Inverter (TCP MODBus)
### SMA Solar Inverter (MODBus TCP)

??? summary "View script"

Expand Down