[y_cable] refactor upgrade firmware API's; Fix vendor and part number…
Browse files Browse the repository at this point in the history
… API's read size for read_eeprom (sonic-net#174)

This PR adds stub functions definition with details as to how firmware upgrade should be implemented by a Y cable vendor.
It also fixes the read_eeprom read size for vendor part number and vendor name retreival API's

Description
Added a stub functions definition with a doc string describing how it should be implemented
Added these API's stub functions for vendors to implement

def download_firmware(physical_port, fwfile)
def activate_firmware(physical_port)
def rollback_firmware(physical_port)

Motivation and Context
Firmware upgrade is a functionality that vendors need to implement, this PR adds the definition's
and a description of how the implementation of this firmware upgrade procedure API's should be implemented
by breaking down the firmware upgrade into above specified sub routines.

Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
  • Loading branch information
vdahiya12 authored Mar 7, 2021
1 parent ed93a15 commit 1673d25
Showing 1 changed file with 66 additions and 20 deletions.
86 changes: 66 additions & 20 deletions sonic_y_cable/y_cable.py
Original file line number Diff line number Diff line change
Expand Up @@ -31,7 +31,6 @@
OFFSET_SWITCH_MUX_DIRECTION = 642
OFFSET_MUX_DIRECTION = 644
OFFSET_ACTIVE_TOR_INDICATOR = 645
OFFSET_MANUAL_SWITCH_COUNT = 669
OFFSET_CONFIGURE_PRBS_TYPE = 768
OFFSET_ENABLE_PRBS = 769
OFFSET_INITIATE_BER_MEASUREMENT = 770
Expand Down Expand Up @@ -92,9 +91,13 @@

MAX_NUM_LANES = 4

# Valid return codes for upgrade_firmware() routine
FIRMWARE_UPGRADE_SUCCESS = 0
FIRMWARE_UPGRADE_FAILURE = 1
# Valid return codes for upgrade firmware routine steps
FIRMWARE_DOWNLOAD_SUCCESS = 0
FIRMWARE_DOWNLOAD_FAILURE = 1
FIRMWARE_ACTIVATE_SUCCESS = 0
FIRMWARE_ACTIVATE_FAILURE = 1
FIRMWARE_ROLLBACK_SUCCESS = 0
FIRMWARE_ROLLBACK_FAILURE = 1

SYSLOG_IDENTIFIER = "sonic_y_cable"

Expand Down Expand Up @@ -995,8 +998,8 @@ def get_part_number(physical_port):
curr_offset = OFFSET_PART_NUMBER

if platform_chassis is not None:
part_result = platform_chassis.get_sfp(physical_port).read_eeprom(curr_offset, 15)
if y_cable_validate_read_data(part_result, 15, physical_port, "Part number") == EEPROM_READ_DATA_INVALID:
part_result = platform_chassis.get_sfp(physical_port).read_eeprom(curr_offset, 16)
if y_cable_validate_read_data(part_result, 16, physical_port, "Part number") == EEPROM_READ_DATA_INVALID:
return EEPROM_ERROR
else:
helper_logger.log_error("platform_chassis is not loaded, failed to get part number")
Expand All @@ -1021,8 +1024,8 @@ def get_vendor(physical_port):
curr_offset = OFFSET_VENDOR_NAME

if platform_chassis is not None:
result = platform_chassis.get_sfp(physical_port).read_eeprom(curr_offset, 15)
if y_cable_validate_read_data(result, 15, physical_port, "Vendor name") == EEPROM_READ_DATA_INVALID:
result = platform_chassis.get_sfp(physical_port).read_eeprom(curr_offset, 16)
if y_cable_validate_read_data(result, 16, physical_port, "Vendor name") == EEPROM_READ_DATA_INVALID:
return EEPROM_ERROR
else:
helper_logger.log_error("platform_chassis is not loaded, failed to get Vendor name")
Expand Down Expand Up @@ -1334,24 +1337,67 @@ def get_nic_voltage(physical_port):
return voltage


def upgrade_firmware(physical_port, fwfile):
""" This routine should facilitate complete firmware
upgrade of the Y cable on all the three ends of the
Y cable of the port specified.
All the components of the Y cable should be upgraded and committed
in their entirety by this single call subroutine.
This should return success code if firmware upgrade is successful
and an error code otherwise.
def download_firmware(physical_port, fwfile):
""" This routine should download and store the firmware on all the
components of the Y cable of the port specified.
This should include any internal transfers, checksum validation etc.
from TOR to TOR or TOR to NIC side of the firmware specified by the fwfile.
This basically means that the firmware which is being downloaded should be
available to be activated (start being utilized by the cable) once this API is
successfully executed.
Note that this API should ideally not require any rollback even if it fails
as this should not interfere with the existing cable functionality because
this has not been activated yet.
Args:
physical_port:
an Integer, the actual physical port connected to a Y cable
fwfile:
a string, a path to the binary file which contains the firmware image
a string, a path to the file which contains the firmware image.
Note that the firmware file can be in the format of the vendor's
choosing (binary, archive, etc.). But note that it should be one file
which contains firmware for all components of the Y-cable
Returns:
an Integer:
a predefined code stating whether the firmware upgrade was successful
or an error code as to what was the cause of firmware upgrade failure
a predefined code stating whether the firmware download was successful
or an error code as to what was the cause of firmware download failure
"""

return FIRMWARE_UPGRADE_SUCCESS
return FIRMWARE_DOWNLOAD_SUCCESS

def activate_firmware(physical_port):
""" This routine should activate the downloaded firmware on all the
components of the Y cable of the port specified.
This API is meant to be used in conjunction with download_firmware API, and
should be called once download_firmware API is succesful.
This means that the firmware which has been downloaded should be
activated (start being utilized by the cable) once this API is
successfully executed.
Args:
physical_port:
an Integer, the actual physical port connected to a Y cable
Returns:
an Integer:
a predefined code stating whether the firmware activate was successful
or an error code as to what was the cause of firmware activate failure
"""

return FIRMWARE_ACTIVATE_SUCCESS

def rollback_firmware(physical_port):
""" This routine should rollback the firmware to the previous version
which was being used by the cable. This API is intended to be called when the
user either witnesses an activate_firmware API failure or sees issues with
newer firmware in regards to stable cable functioning.
Args:
physical_port:
an Integer, the actual physical port connected to a Y cable
Returns:
an Integer:
a predefined code stating whether the firmware rollback was successful
or an error code as to what was the cause of firmware rollback failure
"""

return FIRMWARE_ROLLBACK_SUCCESS