Skip to content

Commit

Permalink
Merge branch 'master' of https://github.com/zxdavb/ramses_rf into eb-…
Browse files Browse the repository at this point in the history
…22f2
  • Loading branch information
silverailscolo committed Nov 11, 2024
2 parents d1ae869 + e469e09 commit 48a1a77
Show file tree
Hide file tree
Showing 14 changed files with 62 additions and 15 deletions.
2 changes: 1 addition & 1 deletion .github/workflows/publish-hatch.yml
Original file line number Diff line number Diff line change
Expand Up @@ -36,7 +36,7 @@ jobs:
run: python -m build

- name: Publish package
uses: pypa/gh-action-pypi-publish@f7600683efdcb7656dec5b29656edb7bc586e597
uses: pypa/gh-action-pypi-publish@fb13cb306901256ace3dab689990e13a5550ffaa
with:
user: __token__
password: ${{ secrets.PYPI_API_TOKEN }}
Expand Down
4 changes: 4 additions & 0 deletions src/ramses_rf/binding_fsm.py
Original file line number Diff line number Diff line change
Expand Up @@ -89,9 +89,11 @@


class Vendor(StrEnum):
CLIMARAD = "climarad"
ITHO = "itho"
NUAIRE = "nuaire"
ORCON = "orcon"
VASCO = "vasco"
DEFAULT = "default"


Expand Down Expand Up @@ -141,6 +143,8 @@ class BindRole(StrEnum):
SCHEME_LOOKUP = {
Vendor.ITHO: {"oem_code": "01"},
Vendor.NUAIRE: {"oem_code": "6C"},
Vendor.CLIMARAD: {"oem_code": "65"},
Vendor.VASCO: {"oem_code": "66"},
Vendor.ORCON: {"oem_code": "67", "offer_to": ALL_DEVICE_ID},
Vendor.DEFAULT: {"oem_code": None},
}
Expand Down
17 changes: 12 additions & 5 deletions src/ramses_tx/fingerprints.py
Original file line number Diff line number Diff line change
Expand Up @@ -43,23 +43,27 @@
"0001001B371B01FEFF": ("FAN", "37", "2019-08-29", "CVE-RF"), # . 31D9, 31DA
"0001001B381B01FEFF": ("FAN", "37", "2020-02-14", "CVE-RF"), # . 31D9, 31DA (and I|042F, I|3120)
"0001001B391B01FEFF": ("FAN", "37", "2021-11-04", "CVE-RF"),
"0001C81C090466FEFF": ("FAN", "29", "0000-00-00", "VMC-17RP01"), # . appears to be an EXT
"0001C8830C0A65FEFF": ("FAN", "37", "2020-12-17", "VMD-07RPS13"), # . ClimaRad VenturaV1x
"0001C81C090466FEFF": ("FAN", "29", "0000-00-00", "VMC-17RP01"), # . appears to be an EXT
"0001C8260A0367FFFF": ("FAN", "29", "0000-00-00", "VMC-15RP01"),
"0001C8260D0467FFFF": ("FAN", "29", "0000-00-00", "VMC-15RP01"), # . 31D9
"0001C8260D0467FFFF": ("FAN", "29", "0000-00-00", "VMC-15RP01"), # . 31D9
"0001C83A0F0866FFFF": ("FAN", "32", "0000-00-00", "VMD-17RPS01"), # . 31D9, 31DA
"0001C85F0E0267FFFF": ("FAN", "32", "0000-00-00", "VMC-15RPS34"), # . Orcon MVS-15
"0001C87D130D67FEFF": ("FAN", "32", "2019-02-28", "VMD-15RMS64"), # . Orcon HRC-300-EcoMax
"0001C87D140D67FEFF": ("FAN", "32", "2019-12-23", "VMD-15RMS64"), # . 31D9, 31DA (and I|042F)
"0001C895050567FEFF": ("FAN", "32", "2020-07-01", "VMD-15RMS86"), # . 31DA, 12A0, 22F7, 2411 (and I|042F, I|313F, I|3120)
"0001C8950B0A67FEFF": ("FAN", "32", "2021-01-21", "VMD-15RMS86"), # . 31D9, 31DA, 12A0, 313F (and I|042F, I|3120)
"0001C81D150765FFFF": ("FAN", "29", "0000-00-00", "VMC-07RP01"), # . ClimaRad MiniBox
"0001C83A190F66FFFF": ("FAN", "32", "0000-00-00", "VMD-17RPS01"), # . Vasco D60Vasco D60

# PIV - usu. Nuaire
"0001C90011006CFEFF": ("FAN", "30", "2016-09-09", "BRDG-02JAS01"), # . NOTE: 30: 31D9, 31DA, 1F09 (a PIV)
"0001C9001D006CFEFE": ("FAN", "30", "2019-07-18", "BRDG-02JAS01"), # . 31D9
# CO2 - some have PIR
"00010028080101FEFF": ("CO2", "37", "2019-04-29", "VMS-12C39"), # . 1298, 31E0, 2E10, 3120, and I|22F1!
"00010028090101FEFF": ("CO2", "37", "2021-01-20", "VMS-12C39"), # . 1298, 31E0, 2E10, 3120 (and I|042F)
"0001C822030166FEFF": ("CO2", "29", "2015-05-07", "VMS-17C01"), # . 1298, 31E0
"0001C822060166FEFF": ("CO2", "37", "2016-12-22", "VMS-17C01"), # . 1298, 31E0
"0001C822060166FEFF": ("CO2", "37", "2016-12-22", "VMS-17C01"), # . 1298, 31E0 (Vasco RF includes REM buttons TODO)
"0001C8500B0167FEFF": ("CO2", "29", "2017-03-09", "VMS-15C16"), # . CO2 sensor (no remote)
"0001C85701016CFFFF": ("CO2", "32", "2016-06-17", "VMS-23C33"), # . 1298, 31E0 (and I|042F)
# HUM
Expand All @@ -70,6 +74,7 @@
"0001C827050167FFFF": ("REM", "29", "0000-00-00", "VMN-15LF01"), # . 22F1, 22F3
"0001C827070167FFFF": ("REM", "29", "0000-00-00", "VMN-15LF01"), # . 22F1, 22F3
"0001C827090167FFFF": ("REM", "29", "2019-02-13", "VMN-15LF01"), # . 22F1, 22F3 (and I|042F)
"0001C8400F0166FFFF": ("REM", "29", "2021-11-01", "VMN-17LMP01"), # . Vasco remote 4-way
"0001C85901016CFFFF": ("REM", "32", "2016-05-31", "VMN-23LMH23"), # . zxdavb 22F1, 1060, 4-way?
"0001C85A01016CFFFF": ("REM", "32", "2016-06-01", "VMN-23LMH23"), # . zxdavb 22F1, 1060, 4-way?
# REM (display, or with CO2 sensor)
Expand Down Expand Up @@ -118,7 +123,7 @@ def check_signature(dev_type: str, signature: str) -> None:
# VMD - Heat recovery unit
# VMC - Mechanical extraction: To integrate in a single fan system
# VMI - User interface with display
# VMN -
# VMN - Remote
# VMS - Sensors platform: CO2, humidity and temperature (and PIR?)

# BRDG-02A55 - Fan of some description
Expand All @@ -133,6 +138,7 @@ def check_signature(dev_type: str, signature: str) -> None:
# VMC-15RP01 - Orcon unit (senseair.com)
# VMC-17RP01 - Vasco C400RF (fan)

# VMD-07RPS13 - FAN - ClimaRad VenturaV1x
# VMD-15RMS64 - FAN - Orcon HRC-350 (Ventiline) / Orcon MVS 15RHB
# VMD-15RMS86 -
# VMD-17RPS01 -
Expand All @@ -141,6 +147,7 @@ def check_signature(dev_type: str, signature: str) -> None:
# VMI-15MC01 - REM - Orcon 15RF with integrated CO2

# VMN-15LF01 - REM - Orcon 15RF 6 button remote
# VMN-17LMP01 - REM - Vasco 4 button remote (NL 2021)
# VMN-23LM33 - REM?
# VMN-23LMH23 - REM - 4 button RF Switch

Expand All @@ -149,7 +156,7 @@ def check_signature(dev_type: str, signature: str) -> None:
# VMS-15C16 - CO2 - CO2 Sensor (no remote)
# VMS-12C39 - CO2 - CO2 Sensor, incl. integrated control, PIR?
# VMS-15CM17 - CO2 - CO2 Sensor
# VMS-17C01 -
# VMS-17C01 - CO2 - CO2 Sensor, incl. integrated control Vasco
# VMS-17HB01 -
# VMS-23C33 - CO2 - CO2 Sensor (no PIR) (e.g. Nuaire DRI-ECO-CO2)
# VMS-23HB33 - HUM - RH/Temp Sensor (e.g. Nuaire DRI-ECO-RH)
Expand Down
5 changes: 3 additions & 2 deletions src/ramses_tx/parsers.py
Original file line number Diff line number Diff line change
Expand Up @@ -139,6 +139,7 @@
# - janvken: 10D0, 1470, 1F70, 22B0, 2411, several others
# - tomkooij: 3110
# - RemyDeRuysscher: 10E0, 31DA (and related), others
# - silverailscolo: 12A0, 31DA, others


from .const import ( # noqa: F401, isort: skip, pylint: disable=unused-import
Expand Down Expand Up @@ -1288,12 +1289,12 @@ def parser_1fc9(payload: str, msg: Message) -> PayDictT._1FC9:
def _parser(seqx: str) -> list[str]:
if seqx[:2] not in ("90",):
assert (
seqx[6:] == payload[6:12]
seqx[6:] == payload[6:12] # [6:12] is repeated
), f"{seqx[6:]} != {payload[6:12]}" # all with same controller
if seqx[:2] not in (
"21", # HVAC, Nuaire
"63", # HVAC
"66", # HVAC, Vasco?
"66", # HVAC, Vasco
"67", # HVAC
"6C", # HVAC
"90", # HEAT
Expand Down
3 changes: 0 additions & 3 deletions src/ramses_tx/ramses.py
Original file line number Diff line number Diff line change
Expand Up @@ -344,9 +344,6 @@
W_: r"^00[0-9A-F]{30}$",
},
Code._1FC9: { # rf_bind
# RP --- 13:035462 18:013393 --:------ 1FC9 018 00-3EF0-348A86 00-11F0-348A86 90-3FF1-956ABD # noqa: E501
# RP --- 13:035462 18:013393 --:------ 1FC9 018 00-3EF0-348A86 00-11F0-348A86 90-7FE1-DD6ABD # noqa: E501
# RP --- 01:145038 18:013393 --:------ 1FC9 012 FF-10E0-06368E FF-1FC9-06368E
SZ_NAME: "rf_bind", # idx-code-dev_id
RQ: r"^00$",
RP: r"^((0[0-9A-F]|F[69ABCF]|[0-9A-F]{2})([0-9A-F]{10}))+$",
Expand Down
5 changes: 5 additions & 0 deletions tests/tests/fingerprints/10e0_xxxx.log
Original file line number Diff line number Diff line change
Expand Up @@ -280,3 +280,8 @@
2022-07-04T14:35:13.010859 095 I --- 37:240038 63:262142 --:------ 10E0 038 0000010028040101FEFFFFFFFFFF030B07E0564D532D31324333390000000000000000000000
2021-07-01T04:44:33.312900 ... I --- 37:258565 63:262142 --:------ 10E0 038 0000010028080101FEFFFFFFFFFF1D0407E3564D532D31324333390000000000000000000000
2021-07-01T09:15:00.949226 083 I --- 37:261128 --:------ 37:261128 10E0 038 000001001B361B01FEFFFFFFFFFF0B0407E34356452D52460000000000000000000000000000
2024-10-16T18:43:52.761437 087 I --- 29:099029 63:262142 --:------ 10E0 029 000001C81D150765FFFFFFFFFFFFFFFFFFFF564D432D30375250303100 # {'description': 'VMC-07RP01', 'manufacturer_sub_id': 'C8', 'product_id': '1D', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'oem_code': '65'} # ClimaRad MiniBox Fan
2024-10-09T11:50:24.287879 123 I --- 37:153226 63:262142 --:------ 10E0 038 000001C8830C0A65FEFFFFFFFFFF110C07E4564D442D30375250533133000000000000000000 # {'description': 'VMD-07RPS13', 'manufacturer_sub_id': 'C8', 'product_id': '83', 'date_1': '2020-12-17', 'date_2': '0000-00-00', 'oem_code': '65'} # ClimaRad Ventura V1x HRU
2024-10-15T21:01:19.293000 083 I --- 32:022222 63:262142 --:------ 10E0 030 000001C83A190F66FFFFFFFFFFFFFFFFFFFF564D442D3137525053303100 # {'description': 'VMD-17RPS01', 'manufacturer_sub_id': 'C8', 'product_id': '3A', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'oem_code': '66'} # Vasco D60 HRU
2024-10-04 22:24:58.581000 ... I --- 29:091138 63:262142 --:------ 10E0 038 000001C8400F0166FFFFFFFFFFFF0E0207E3564D4E2D31374C4D503031000000000000000000 # {'description': 'VMN-17LMP01', 'manufacturer_sub_id': 'C8', 'product_id': '40', 'date_1': '2019-02-14', 'date_2': '0000-00-00', 'oem_code': '66'} # Vasco 4 button RF remote
2024-10-09T11:51:49.472184 059 I --- 37:117647 63:262142 --:------ 10E0 038 000001C822060166FEFFFFFFFFFF160C07E0564D532D31374330310000000000000000000000 # {'description': 'VMS-17C01', 'manufacturer_sub_id': 'C8', 'product_id': '22', 'date_1': '2016-12-22', 'date_2': '0000-00-00', 'oem_code': '66'} # Vasco CO2 sensor
2 changes: 2 additions & 0 deletions tests/tests/fingerprints/hvac/29_VMC-07RP01.log
Original file line number Diff line number Diff line change
@@ -0,0 +1,2 @@
# ClimaRad MiniBox Fan
2024-10-16T18:43:52.761437 087 I --- 29:099029 63:262142 --:------ 10E0 029 000001C81D150765FFFFFFFFFFFFFFFFFFFF564D432D30375250303100 # {'description': 'VMC-07RP01', 'manufacturer_sub_id': 'C8', 'product_id': '1D', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'oem_code': '65'}
2 changes: 2 additions & 0 deletions tests/tests/fingerprints/hvac/29_VMN-07LM01.log
Original file line number Diff line number Diff line change
@@ -0,0 +1,2 @@
# ClimaRad 4-button remote
2024-10-16T21:32:07.084793 073 I --- 29:123150 63:262142 --:------ 10E0 029 000001C8410D0165FFFFFFFFFFFF0D0407DF564D4E2D30374C4D303100 # {'description': 'VMN-07LM01', 'manufacturer_sub_id': 'C8', 'product_id': '41', 'date_1': '2015-04-13', 'date_2': '0000-00-00', 'oem_code': '65'}
2 changes: 2 additions & 0 deletions tests/tests/fingerprints/hvac/29_VMN-17LMP01.log
Original file line number Diff line number Diff line change
@@ -0,0 +1,2 @@
# Vasco 4 button RF remote
2024-10-04 22:24:58.581000 ... I --- 29:091138 63:262142 --:------ 10E0 038 000001C8400F0166FFFFFFFFFFFF0E0207E3564D4E2D31374C4D503031000000000000000000 # {'description': 'VMN-17LMP01', 'manufacturer_sub_id': 'C8', 'product_id': '40', 'date_1': '2019-02-14', 'date_2': '0000-00-00', 'oem_code': '66'}
5 changes: 3 additions & 2 deletions tests/tests/fingerprints/hvac/32_VMD-17RPS01.log
Original file line number Diff line number Diff line change
@@ -1,2 +1,3 @@

2021-11-08T07:02:27.941100 ... I --- 32:023459 63:262142 --:------ 10E0 030 000001C83A0F0866FFFFFFFFFFFFFFFFFFFF564D442D3137525053303100
# Vasco D60 HRU
2021-11-08T07:02:27.941100 ... I --- 32:023459 63:262142 --:------ 10E0 030 000001C83A0F0866FFFFFFFFFFFFFFFFFFFF564D442D3137525053303100 # {'oem_code': '66', 'manufacturer_sub_id': 'C8', 'product_id': '3A', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'description': 'VMD-17RPS01'}
2024-10-15T21:01:19.293000 083 I --- 32:022222 63:262142 --:------ 10E0 030 000001C83A190F66FFFFFFFFFFFFFFFFFFFF564D442D3137525053303100 # {'oem_code': '66', 'manufacturer_sub_id': 'C8', 'product_id': '3A', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'description': 'VMD-17RPS01'}
3 changes: 3 additions & 0 deletions tests/tests/fingerprints/hvac/37_VMD-07RPS13.log
Original file line number Diff line number Diff line change
@@ -0,0 +1,3 @@
# ClimaRad Ventura V1x HRU

2024-10-09T11:50:24.287879 123 I --- 37:153226 63:262142 --:------ 10E0 038 000001C8830C0A65FEFFFFFFFFFF110C07E4564D442D30375250533133000000000000000000 # {'description': 'VMD-07RPS13', 'manufacturer_sub_id': 'C8', 'product_id': '83', 'date_1': '2020-12-17', 'date_2': '0000-00-00', 'oem_code': '65'}
3 changes: 3 additions & 0 deletions tests/tests/fingerprints/hvac/99_VMS-17C01.log
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,9 @@
# CONFIRMED:
2023-02-18T19:56:43.537735 059 I --- 29:136571 63:262142 --:------ 10E0 038 000001C822030166FEFFFFFFFFFF070507DF564D532D31374330310000000000000000000000 # {"signature": "0001C822030166FEFF", "oem": "Vasco"}

2024-10-09T11:51:49.472184 059 I --- 37:117647 63:262142 --:------ 10E0 038 000001C822060166FEFFFFFFFFFF160C07E0564D532D31374330310000000000000000000000 # {'description': 'VMS-17C01', 'manufacturer_sub_id': 'C8', 'product_id': '22', 'date_1': '2016-12-22', 'date_2': '0000-00-00', 'oem_code': '66'}
# Vasco CO2 sensor with 1 touch button (cycles through speed steps)


# SUSPECTED:

Expand Down
10 changes: 9 additions & 1 deletion tests/tests/parsers/code_10e0.log
Original file line number Diff line number Diff line change
Expand Up @@ -99,10 +99,18 @@
2023-10-26T00:00:00.000000 ... I --- 37:211856 --:------ 37:211856 10E0 038 000001001B391B01FEFFFFFFFFFF040B07E54356452D52460000000000000000000000000000 # {'description': 'CVE-RF', 'manufacturer_sub_id': '00', 'product_id': '1B', 'date_2': '0000-00-00', 'date_1': '2021-11-04', 'oem_code': '01'} # Manufacturer is Buva?
2022-11-03T22:50:34.060486 ... I --- 37:255297 63:262142 --:------ 10E0 038 00000100290A0201FFFFFFFFFFFF140407E5564D532D31324842313600000000000000000000 # {'description': 'VMS-12HB16', 'manufacturer_sub_id': '00', 'product_id': '29', 'date_2': '0000-00-00', 'date_1': '2021-04-20', 'oem_code': '01'} #

# oem_code '66' - Vasco CH/DHW & HVAC
# oem_code '65' - ClimaRad HVAC
2024-10-09T11:50:24.287879 123 I --- 37:153226 63:262142 --:------ 10E0 038 000001C8830C0A65FEFFFFFFFFFF110C07E4564D442D30375250533133000000000000000000 # {'description': 'VMD-07RPS13', 'manufacturer_sub_id': 'C8', 'product_id': '83', 'date_1': '2020-12-17', 'date_2': '0000-00-00', 'oem_code': '65'} # ClimaRad VenturaV1x
2024-10-16T18:43:52.761437 087 I --- 29:099029 63:262142 --:------ 10E0 029 000001C81D150765FFFFFFFFFFFFFFFFFFFF564D432D30375250303100 # {'description': 'VMC-07RP01', 'manufacturer_sub_id': 'C8', 'product_id': '1D', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'oem_code': '65'} # ClimaRad MiniBox Fan
2024-10-16T21:32:07.084793 073 I --- 29:123150 63:262142 --:------ 10E0 029 000001C8410D0165FFFFFFFFFFFF0D0407DF564D4E2D30374C4D303100 # {'description': 'VMN-07LM01', 'manufacturer_sub_id': 'C8', 'product_id': '41', 'date_1': '2015-04-13', 'date_2': '0000-00-00', 'oem_code': '65'} # ClimaRad 4-button remote

# oem_code '66' - Vasco CH/DHW & HVAC
2023-02-19T11:37:59.549235 072 RP --- 29:079817 30:006056 --:------ 10E0 029 000001C81C090466FEFFFFFFFFFFFFFFFFFF564D432D31375250303100 # {'description': 'VMC-17RP01', 'manufacturer_sub_id': 'C8', 'product_id': '1C', 'date_2': '0000-00-00', 'date_1': '0000-00-00', 'oem_code': '66'} # Vasco C400RF extraction unit (EXT, not HRU/PIV)
2023-02-18T19:56:43.537735 059 I --- 29:136571 63:262142 --:------ 10E0 038 000001C822030166FEFFFFFFFFFF070507DF564D532D31374330310000000000000000000000 # {'description': 'VMS-17C01', 'manufacturer_sub_id': 'C8', 'product_id': '22', 'date_2': '0000-00-00', 'date_1': '2015-05-07', 'oem_code': '66'} # CO2 sensor
2024-10-09T11:51:49.472184 059 I --- 37:117647 63:262142 --:------ 10E0 038 000001C822060166FEFFFFFFFFFF160C07E0564D532D31374330310000000000000000000000 # {'description': 'VMS-17C01', 'manufacturer_sub_id': 'C8', 'product_id': '22', 'date_1': '2016-12-22', 'date_2': '0000-00-00', 'oem_code': '66'} # CO2 sensor
2024-10-04 22:24:58.581000 ... I --- 29:091138 63:262142 --:------ 10E0 038 000001C8400F0166FFFFFFFFFFFF0E0207E3564D4E2D31374C4D503031000000000000000000 # {'description': 'VMN-17LMP01', 'manufacturer_sub_id': 'C8', 'product_id': '40', 'date_1': '2019-02-14', 'date_2': '0000-00-00', 'oem_code': '66'} # Vasco 4-button remote
2023-02-19T11:37:53.826773 032 I --- 30:006056 63:262142 --:------ 10E0 038 000001C848260066FEFEFFFFFFFF1C0B07E3425244472D3032454D3233000000000000000000 # {'description': 'BRDG-02EM23', 'manufacturer_sub_id': 'C8', 'product_id': '48', 'date_2': '0000-00-00', 'date_1': '2019-11-28', 'oem_code': '66'} # Vasco gateway (more like a CTL, but also RFG)
2024-10-15T21:01:19.293000 083 I --- 32:022222 63:262142 --:------ 10E0 030 000001C83A190F66FFFFFFFFFFFFFFFFFFFF564D442D3137525053303100 # {'description': 'VMD-17RPS01', 'manufacturer_sub_id': 'C8', 'product_id': '3A', 'date_1': '0000-00-00', 'date_2': '0000-00-00', 'oem_code': '66'} # Vasco D60 HRU

# oem_code '67' - Orcon HVAC
2023-09-20 20:12:43.056000 ... I --- 32:161205 63:262142 --:------ 10E0 038 000001C87D130D67FEFFFFFFFFFF1C0207E3564D442D3135524D533634000000000000000000 # {'description': 'VMD-15RMS64', 'manufacturer_sub_id': 'C8', 'product_id': '7D', 'date_2': '0000-00-00', 'date_1': '2019-02-28', 'oem_code': '67'} # Orcon HRC-300-EcoMax
Expand Down
14 changes: 13 additions & 1 deletion tests/tests/parsers/code_1fc9.log
Original file line number Diff line number Diff line change
@@ -1,5 +1,8 @@
########################################################################################
### Heat domain ###
# RP --- 13:035462 18:013393 --:------ 1FC9 018 00-3EF0-348A86 00-11F0-348A86 90-3FF1-956ABD # noqa: E501
# RP --- 13:035462 18:013393 --:------ 1FC9 018 00-3EF0-348A86 00-11F0-348A86 90-7FE1-DD6ABD # noqa: E501
# RP --- 01:145038 18:013393 --:------ 1FC9 012 FF-10E0-06368E FF-1FC9-06368E

# CTL binding to an OTB (FC|0008, FC|3150, FB|3150, FC|1FC9): : Domain id FB|3150 (+FC)
2020-11-23T14:35:23.043166 045 I --- 01:078710 --:------ 01:078710 1FC9 024 FC0008053376FC3150053376FB3150053376FC1FC9053376 # {'phase': 'offer', 'bindings': [['FC', '0008', '01:078710'], ['FC', '3150', '01:078710'], ['FB', '3150', '01:078710'], ['FC', '1FC9', '01:078710']]}
Expand Down Expand Up @@ -70,7 +73,6 @@
2022-01-07T14:48:48.604387 ... W --- 30:248208 01:054173 --:------ 1FC9 012 0010E07BC9900012907BC990 # {'phase': 'accept', 'bindings': [['00', '10E0', '30:248208'], ['00', '1290', '30:248208']]}
2022-01-07T14:48:48.769229 ... I --- 01:054173 30:248208 --:------ 1FC9 006 00FFFF04D39D # {'phase': 'confirm', 'bindings': [['00', 'FFFF', '01:054173']]}


# The first BDR91 (which has a 3B00 in the payload) is the TPI relay (it turns the boiler on/off), the 2nd is not.
2020-01-01T20:32:58.273000 ... RQ --- 18:013393 13:237335 --:------ 1FC9 001 00
2020-01-01T20:32:58.297000 ... RP --- 13:237335 18:013393 --:------ 1FC9 012 003EF0379F17003B00379F17
Expand Down Expand Up @@ -99,3 +101,13 @@
2022-08-17T19:32:32.785062 ... I --- 37:155617 --:------ 37:155617 1FC9 024 0022F1965FE10022F3965FE16710E0965FE1001FC9965FE1 # {'phase': 'offer', 'bindings': [['00', '22F1', '37:155617'], ['00', '22F3', '37:155617'], ['67', '10E0', '37:155617'], ['00', '1FC9', '37:155617']]}
2022-08-17T19:32:34.825700 ... W --- 32:155617 37:155617 --:------ 1FC9 012 0031D9825FE10031DA825FE1 # {'phase': 'accept', 'bindings': [['00', '31D9', '32:155617'], ['00', '31DA', '32:155617']]}
2022-08-17T19:32:35.418914 ... I --- 37:155617 32:155617 --:------ 1FC9 001 00 # {'phase': 'confirm', 'bindings': [['00']]}

# Vasco remote (22F1/3) binding to a D60 HRU FAN (31D9/A)
2024-11-07T14:39:29.639500 072 I --- 29:091138 --:------ 29:091138 1FC9 024 0022F17564020022F37564026610E0756402001FC9756402 # {'phase': 'offer', 'bindings': [['00', '22F1', '29:091138'], ['00', '22F3', '29:091138'], ['66', '10E0', '29:091138'], ['00', '1FC9', '29:091138']]}
2024-11-07T14:39:29.687203 083 W --- 32:022222 29:091138 --:------ 1FC9 012 0031D98056CE0031DA8056CE # {'phase': 'accept', 'bindings': [['00', '31D9', '32:022222'], ['00', '31DA', '32:022222']]}
2024-11-07T14:39:29.693284 071 I --- 29:091138 32:022222 --:------ 1FC9 001 00 # {'phase': 'confirm', 'bindings': [['00']]}

# ClimaRad remote (31D9) binding to a ClimaRad MiniBox FAN (31D9)
2024-11-07T19:32:38.578052 ... I --- 29:123160 --:------ 29:123160 1FC9 012 0031D975E118001FC975E118 # {'phase': 'offer', 'bindings': [['00', '31D9', '29:123160'], ['00', '1FC9', '29:123160']]}
2024-11-07T13:01:37.338144 090 W --- 29:099029 29:123150 --:------ 1FC9 006 0031D97582D5 # {'phase': 'accept', 'bindings': [['00', '31D9', '29:099029']]}
2024-11-07T13:01:37.355235 092 I --- 29:123150 29:099029 --:------ 1FC9 001 00 # {'phase': 'confirm', 'bindings': [['00']]}