Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

DT_THERM=6*DT and DIABATIC_FIRST = False #94

Merged
merged 2 commits into from
Aug 7, 2024
Merged
Show file tree
Hide file tree
Changes from 1 commit
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
7 changes: 4 additions & 3 deletions MOM_input
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
! This file was written by the model and records the non-default parameters used at run-time.

! === module MOM ===
DIABATIC_FIRST = True ! [Boolean] default = False
DIABATIC_FIRST = False ! [Boolean] default = False
! If true, apply diabatic and thermodynamic processes, including buoyancy
! forcing and mass gain or loss, before stepping the dynamics forward.
USE_REGRIDDING = True ! [Boolean] default = False
Expand All @@ -16,17 +16,18 @@ DT = 1800.0 ! [s]
! The (baroclinic) dynamics time step. The time-step that is actually used will
! be an integer fraction of the forcing time-step (DT_FORCING in ocean-only mode
! or the coupling timestep in coupled mode.)
DT_THERM = 3600.0 ! [s] default = 1800.0
DT_THERM = 10800.0 ! [s] default = 1800.0
! The thermodynamic and tracer advection time step. Ideally DT_THERM should be
! an integer multiple of DT and less than the forcing or coupling time-step,
! unless THERMO_SPANS_COUPLING is true, in which case DT_THERM can be an integer
! multiple of the coupling timestep. By default DT_THERM is set to DT.
THERMO_SPANS_COUPLING = True
HFREEZE = 10.0 ! [m] default = -1.0
! If HFREEZE > 0, melt potential will be computed. The actual depth over which
! melt potential is computed will be min(HFREEZE, OBLD), where OBLD is the
! boundary layer depth. If HFREEZE <= 0 (default), melt potential will not be
! computed.
DTBT_RESET_PERIOD = 0.0 ! [s] default = 3600.0
DTBT_RESET_PERIOD = 10800.0 ! [s] default = 3600.0
! The period between recalculations of DTBT (if DTBT <= 0). If DTBT_RESET_PERIOD
! is negative, DTBT is set based only on information available at
! initialization. If 0, DTBT will be set every dynamics time step. The default
Expand Down
2 changes: 1 addition & 1 deletion config.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -13,7 +13,7 @@ ncpus: 48
jobfs: 10GB
mem: 192GB

walltime: 01:00:00
walltime: 04:00:00
aekiss marked this conversation as resolved.
Show resolved Hide resolved
jobname: 1deg_jra55do_ryf

model: access-om3
Expand Down
4 changes: 2 additions & 2 deletions nuopc.runconfig
Original file line number Diff line number Diff line change
Expand Up @@ -286,15 +286,15 @@ CLOCK_attributes::
history_ymd = -999
ice_cpl_dt = 99999 #not used
lnd_cpl_dt = 99999 #not used
ocn_cpl_dt = 3600
ocn_cpl_dt = 1800

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

It is not necessarily to change the value of ocn_cpl_dt unless stop_option is nsteps. I can do a cherry pick to add comments right after this parameter for all configurations. COSIMA/access-om3#157 (comment)

restart_n = 1
restart_option = nmonths
restart_ymd = -999
rof_cpl_dt = 99999 #not used
start_tod = 0
start_ymd = 19000101
stop_n = 1
stop_option = nmonths
stop_option = nyears
aekiss marked this conversation as resolved.
Show resolved Hide resolved
stop_tod = 0
stop_ymd = -999
tprof_n = -999
Expand Down
2 changes: 1 addition & 1 deletion nuopc.runseq
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
runSeq::
@3600
@1800
MED med_phases_aofluxes_run
MED med_phases_prep_ocn_accum
MED med_phases_ocnalb_run
Expand Down