Version 3.2.0-b1+2
Pre-release
Pre-release
Compatible files:
- DuetSoftwareFramework 3.2.0 or newer
- RepRapFirmware 2 or newer (1.2x may work but untested)
Changed behaviour:
- Plugins may now be loaded. Refer to the
plugins
directory for further details - The Height Map has been moved to a built-in plugin (see Settings -> General -> Plugins)
- Increased maximum editor size from 16MiB to 32MiB
- JSON outputs are automatically formatted in the Code Console
- Replaced
/sys/dwc2-
JSON files with/sys/dwc-
(rename them manually to restore your DWC settings) - Option to revert to DWC1 has been removed
Bug fixes:
- Fixed some incompatibilities to RRFv2
- Code input occasionally required enter to be pressed twice to send a code
- Base URL as defined by compile options was not respected in the connectors
- Depending on the configuration inputs for bed/chamber heaters were disabled
- Under special circumstances the "Reset heater fault" dialog could never time out
Hotfixes since 3.2.0-b1:
- When filament monitors were configured no connection could be established
- Code replies after HTTP code 503 were not properly assigned to codes
- Make new directory wasn't working any more