Toolbox expects SE/STE input sorted by echo and flip angle whereas BIDS sorts by flip angle then echo #46
Comments
If I understand the issue that @nbeliy has correctly, then it is that the expected order of input for the hMRI toolbox is based on an assumed ordering derived from Siemens DICOMs that goes:
whereas the field names specified in BIDS would give the order:
This seems like it should be fixed by simply sorting the input by echo time (which should always be defined, I think). |
I think it's an issue of mostly documentation. The hMRI toolbox don't tell explicetly in which order the maps are passed. Sorting files internally in hMRI toolbox is difficult -- in current implementation the metadata is retrieved only from the first file. Solutions:
Personally I prefer second solution, because it's explicit and transparent. But, it will require the change of subjob parameter change. From technical point of view, all three solutions are not complicated to implement. |
Could you check whether 8a4a7de fixes the issue for you? It reads in the echo times for each of the volumes and tries to distinguish "bids order" from "standard order" based on that. |
It should fix, but it may be not robust agains weird bids names. Something like: ET = unique(b1map_params.b1acq.EchoTimes, 'sorted');
V_SE = V(find(b1map_params.b1acq.EchoTimes == ET(1)));
V_TSE = V(find(b1map_params.b1acq.EchoTimes == ET(2))); |
Thanks; that's a good suggestion which I'll try and implement. |
OK, this branch should now fix the problem relatively generally: https://github.com/hMRI-group/hMRI-toolbox/tree/SDAM |
Will it be also usefull to retrieve also flip angles from all files, same as echo times? With failsafe if retrieved FA is 0, then trying to use The |
I wouldn't want to rely on FlipAngle being 0, as this may be entirely specific to a given sequence (e.g. FlipAngle could instead be the excitation flip angle, which is completely different from the "spin echo" flip angle). This again goes back to decisions needing to be made on how to represent this information in the sequence and how to extract this information from the image header files (#16). |
Ok then, even if it seems little bit strange for me. For classic metadata: For bids metadata: If needed I can try to provide prototypes for these issues. |
This issue was giving me trouble. for a flip there are two echos One solution is to use use bids query to grep the correct file and feed to the input of the code in the correct order. |
@SherS2, Does the solution I proposed (which involves sorting by echo time; see PR #41) not work for you? |
@lukeje I think that your solution is better than mine. |
@SherS2 Thanks; I hope we will have time to get round to that PR at the PR meeting in August. |
@lukeje sure. We can discuss this during PR meeting I was thinking about using the 'bids query' to feed the input files to the matlabbatch in the correct order. You are implementing the solution inside the toolbox. That is the ideal solution. I don't need to worry about the order while putting inputs into the toolbox. |
I think it's the best procedure, the bids-matlab queries, but don't forget to crosscheck the order in which bids-matlab |
@nbeliy @SherS2 Unfortunately I have come across datasets (namely, all the datasets measured at the MPI-CBS in Leipzig) where the lower TE is the stimulated echo, which causes the TE-checking to break. I have thus decided to make it optional for now. I have added an example config file to the branch which shows how to set the flag if you want the TE-checking turned on. Since we are taking this path for the TEs, would it be worthwhile to do something similar for checking the flip angles in the metadata? As background, this problem occurs because, in common implementations of the 3D-SE/STE B1 mapping sequence, the TEs that are written into the DICOM headers are those which are chosen in the protocol editor on the scanner. However only the first TE is used to set the timing for the sequence, and so the second TE can be chosen arbitrarily. If the second TE is not manually set to be longer than the first, then sorting by TE will give the "wrong" order. Note that this also seems to be the case for the reference dataset, where the second TE of 130 ms is not in any real sense the TE of the stimulated echo, and so it is just a coincidence that it is longer than the first TE. A suggestion I would have going forward is that the TE written to the header of the STE DICOMs should be the time since excitation (i.e. the first TE + the mixing time). This would also have the benefit of encoding the mixing time in the header. If I get time I will make this suggestion on the qMRI-BIDS repository... |
@luke I use acqpar.AcquisitionNumber and acqpar.EchoNumbers to name the files in BIDS format. if acqpar.AcquisitionNumber and acqpar.EchoNumbers are available in the JSON of the BIDS JSON file, then you could sort it easily (also verify the order before processing). |
@lukeje The ideal solution is to split input files in 2 groups: SE and STE, thus removing the confusion. Unfortunately it will require change in function signature and compatibility issues. An alternative is to assume (again dangerous) that first echo number encountered is SE, and second is STE (stable instead of sorted): ET = unique(b1map_params.b1acq.EchoTimes, 'stable');
V_SE = V(find(b1map_params.b1acq.EchoTimes == ET(1)));
V_TSE = V(find(b1map_params.b1acq.EchoTimes == ET(2))); In both naming schemas, the echo index goes in acquisition order. In any case, that should be given in documentation (mbatch). |
@SherS2 The aim of the changes is to make it so that you can just give all the qMRI-BIDS compatible SE/STE data as input and the toolbox will sort it and extract the relevant metadata. This should be the case in the latest version of #41 if you modify the b1 processing metadata input in line with this file. @nbeliy I guess you mean changing the batch input system so that the SE and STE files are separate fields? I don't want to do that as it will (a) require the user to be able to tell which is which and (b) break all current scripts. I have thus gone for the approach mentioned in my response to Siya. @SherS2 @nbeliy Is there already a public qMRI-BIDS-compatible 3D-EPI SE/STE B1 mapping dataset I can test it out on? |
@SherS2 @nbeliy I found the BIDS-ified reference MPM dataset, so I'll test it out on that. |
Moving discussion from #45 here.