SONiC NPU MDIO access support and gbsyncd docker enhancement HLD #1045
Changes from all commits
8ecd4df
9e40a3a
e4c2d18
0a6cfa7
50349ff
25c9584
2ebc8a7
ab544d5
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,345 @@ | ||
# SONiC NPU MDIO access support and gbsyncd docker enhancement HLD | ||
|
||
#### Rev 0.3 | ||
|
||
## Table of Content | ||
* [List of Tables](#list-of-tables) | ||
* [Revision](#revision) | ||
* [Scope](#scope) | ||
* [Definitions/Abbreviations](#definitionsabbreviations) | ||
* [Document/References](#documentreferences) | ||
* [Overview](#overview) | ||
* [Requirements](#requirements) | ||
* [Architecture Design](#architecture-design) | ||
* [High-Level Design](#High-Level-Design) | ||
* [SAI API](#SAI-API) | ||
* [Configuration and management](#Configuration-and-management) | ||
* [Restrictions/Limitations](#restrictionslimitations) | ||
* [Testing Requirements/Design](#testing-requirementsdesign) | ||
|
||
## List of Tables | ||
- [Table 1: Abbreviations](#table-1-abbreviations) | ||
- [Table 2: References](#table-2-references) | ||
|
||
### Revision | ||
| Rev | Date | Author | Change Description | | ||
|:----:|:----------:|:-----------------:|:-----------------------------------------------:| | ||
| 0.1 | 07/31/2022 | Jiahua Wang | Initial version | | ||
| 0.2 | 08/03/2022 | Jiahua Wang | Fix title and references | | ||
| 0.3 | 08/12/2022 | Jiahua Wang | Overloading VendoSai class constructor | | ||
| 0.4 | 09/12/2022 | Jiahua Wang | Add testing requirements/design section | | ||
| 0.5 | 09/13/2022 | Jiahua Wang | Define PHY MDIO access function names | | ||
| 0.6 | 09/27/2022 | Jiahua Wang | VendorPaiDll class inheriting VendorSai class | | ||
| 0.7 | 09/28/2022 | Jiahua Wang | Change to VendorPai class, add paiInstance | | ||
|
||
### About this Manual | ||
|
||
This document provides general information about gearbox MDIO functionality and implementation in utilizing the PAI library and gbsyncd for SONiC. This document also provides a design to build a single gbsyncd docker to work with various PAI library and different external PHY access method. | ||
|
||
### Scope | ||
This document describes the high level design of the gbsyncd mdio access function with the focus on using the mdio bus from the switch NPU. This function primarily consists of two new syncd classes, one new mdio access library, addition of SAI switch api and changes in switch NPU configuration. The function helps the gbsyncd and PAI library to access the mdio devices (External PHYs). One of the new syncd class also helps to dynamically load PAI library and MDIO access library at runtime so that only a single gbsyncd docker can work for different switch platforms with external PHY. | ||
|
||
### Definitions/Abbreviations | ||
|
||
#### Table 1 Abbreviations | ||
|
||
| **Term** | **Meaning** | | ||
|------------------|----------------------------------------------------------------------------| | ||
| gbsyncd | The daemon and docker servicing external PHY configuration processing | | ||
| IPC | Inter-Process-Communication | | ||
| MDIO | Management Data Input/Output used to access the registers of external PHY | | ||
| MDIO Clause 22 | Defined in Clause 22 of IEEE RFC802.3 to access 32 registers on 32 ports | | ||
| MDIO Clause 45 | Defined in Clause 45 of the 802.3ae to access 65,536 registers in 32 devices on 32 ports | | ||
| PAI | Switch Abstraction Interface used for external PHY programming | | ||
| PHY | Physical Layer chip devices (commonly found on Ethernet devices) | | ||
| SAI | Switch Abstraction Interface | | ||
|
||
### Document/References | ||
|
||
#### Table 2 References | ||
|
||
| **Document** | **Location** | | ||
|------------------------------------|---------------| | ||
| SONiC Gearbox Manager High Level Design Document | [https://github.com/sonic-net/SONiC/blob/master/doc/gearbox/gearbox_mgr_design.md](https://github.com/sonic-net/SONiC/blob/master/doc/gearbox/gearbox_mgr_design.md) | | ||
|
||
|
||
### Overview | ||
|
||
The Ethernet switches of today often have PHY, re-timer and mux. Some PHY is internal to the switch NPU, but most PHY is external to the switch NPU. From software point of view, PHY is considered as internal when the PHY is supported by the SAI or SDK of the switch NPU. External PHY does not have support by the switch NPU SAI/SDK. External PHY requires PAI support. In SONiC gearbox framework, there is a gbsyncd docker and daemon servicing the externl PHY configuration processing. | ||
|
||
### Requirements | ||
|
||
The syncd docker and daemon use the SAI library to service the NPU programming. The SAI library uses PCIe to access the NPU hardware. The gbsyncd docker and daemon use the PAI library to service the external PHY configuration processing. The PAI library usualy uses MDIO to access the PHY hardware. | ||
|
||
It depends on the switch hardware design that the external PHY could be connected to a FPGA or CPLD based MDIO controller or a switch NPU MDIO bus. The FPGA or CPLD based MDIO controller often has linux kernel driver and provides linux sysfs programming interface. The switch NPU MDIO bus uses SAI library hence an Inter-Process-Communication (IPC) mechanism is required between the syncd daemon and gbsyncd daemon. | ||
![libPAI MDIO access](images/PAI-MDIO.png) | ||
|
||
There are 2 mdio access modes: clause 45 and clause 22. Some external PHY uses clause 45 mdio while other external PHY uses clause 22 mdio. The switch NPU sai switch api should distinguish the 2 modes. | ||
|
||
When a configured platform target is built, there is only one syncd docker as the SAI library for the configured platform will cover all the device with switch NPU in the same configured platform class. Although the gbsyncd docker is very much similar to the syncd docker, there could be many gbsyncd docker required as there are different PAI library for different PHY and MDIO access method. Our goal is to build a single gbsyncd docker to cover all PHY and MDIO access method. | ||
|
||
### Architecture Design | ||
|
||
There are many choices for the IPC mechanism between the syncd daemon and gbsyncd daemon. One performance requirement is that it should finsh firmware download within a reasonable time. Our design choice is to use the Unix socket as the IPC mechanism. Our design has the MDIO IPC server in the syncd daemon with its own thread. A new syncd class MdioIpcServer is added to start a new thread, to create an unix socket, to listen on the socket, to accept connection and to read/reply IPC messages. | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Could we consider using connectionless unix socket for avoiding open/accept/close connection? There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. One of the design goals is to easily accommodate multiple clients at the same time. The unix socket type used in the design helps to achieve this goal. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Unix socket with SOCK_DGRAM could do same with epoll/select. Clients are able to be identified by client addresses. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. It can be done by either socket types. It is easier to track clients using connection. |
||
|
||
There is a corresponding MDIO access IPC client code in the form of dynamic link library which provides the flexiblity to load the library at runtime. Assuming the MDIO access library for sysfs is also in the form of dynamic library, gbsyncd can select the MDIO access library at runtime based on some configuration in the gearbox\_config.json file. | ||
|
||
The same gearbox\_config.json file already has the information of the PAI library name. The information can be used to dynamically load the PAI library at runtime. | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I think to load MDIO client library and PAI library at runtime looks over-designed. The current design of gbsyncd having a dynamical linked PHY library is simple and straightforward. It also eases the gbsyncd docker build. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Our design is to have a single gbsyncd container. When a new PAI/external PHY type is added, only the new library is added to the gbsyncd container, but not to create another gbsyncd container. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Each PAI/PHY type may also need specific psai.profile for initialization. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. This design does not aggregate PHYs. Without extra software components/changes, each PHY is still treated as individual PHY. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more.
The new library may depend on 1/ env setup 2/ init PHY config file 3/ other lib/sdk, etc, as to work and manage new PHY. Would you describe the details of how to handle them, while loading the library with dlopen? There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. When a new platform with external PHY is added to the SONiC image. The sonic device data directories will have the new init PHY config file, gearbox config file and PHY config file in the new "platform" and "hwsku" directories. The new PAI/PHY driver libraries need to be added to the 'gbsyncd' docker when the SONiC image is built. dlopen()/dlsym() do not require LD_LIBRARY_PATH or ldconfig setup. As long as the new library has a distinguish path/name, it can be open and loaded at runtime. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I see dlopen()/dlsym() do not require LD_LIBRARY_PATH. My point is the library might need its runtime context setup in gbsyncd docker. How to dynamically make it ready?
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I understand that the syncd needs a profile name passed by -p option, e.g. |
||
|
||
The informationn of PHY device using clause 22 mdio can also be added to the gearbox\_config.json file. It will help to decide the mdio access mode at runtime. | ||
|
||
![syncd gbsyncd MDIO IPC](images/MDIO-IPC.png) | ||
|
||
A new syncd class VendorPai is used by gbsyncd instance to handle PAI. The VendorPai class has inheritance from the VendorSai class. The syncd class VendorSai currently only links SAI/PAI library with the SAI/PAI library path determined at syncd build time. The new VendorPai class can have the PAI library path as one of the arguments for its constructor. The MDIO access library path can be another arguments for the constructor of the VendorPai class. Both the PAI library and the MDIO access library can be dynamically linked by syncd in gbsyncd docker at run time. | ||
|
||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. As above, overloading There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. The reason is the same as above. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. maybe it should not be called Dll, and just by simple VendorPai There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Changed class name to VendorPai |
||
### High-Level Design | ||
|
||
The high level design of the gbsyncd mdio access function using the mdio bus from the switch NPU and using single gbsyncd docker in SONiC image can be covered in the following points: | ||
|
||
- It is an enhancement to the sonic gearbox framework. | ||
- Syncd, SAI and some sonic device files are modified. | ||
- There are 2 repositories that would be changed, sonic-sairedis and SAI. | ||
- gbsyncd will have dependencies on syncd to create the Unix IPC socket. | ||
- Syncd will have new classes for the MDIO IPC server and for the parser of gearbox configuration. | ||
- There is a new MDIO IPC client library is added. | ||
- The new MDIO IPC client library code can be under syncd, but is not linked to syncd at build time. | ||
- External PHY firmware download time always has performance requirements/impact. | ||
- For debugging, beside the syslog logging, the Unix socket IPC mechanism can be simulated by socat. | ||
- The current change is only tested on the Broadcom switch, but should work for other switch. | ||
- SAI switch api has added the mido clause 22 access functions. | ||
- The SaiInterface class has added the mdio clause 45/22 read/write virtual functions. | ||
- The VendoSai class overrides the mdio clause 45/22 read/write virtual functions. | ||
- New keys are added to the gearbox configuration file "gearbox\_config.json". | ||
- During the warmboot, the creation of the Unix IPC socket and connection is the same as of coldboot. | ||
- The platform module software should not reset the external PHY during warmboot. | ||
|
||
The VendorPai class will inherit most member functions from the VendorSai class. The VendorSai class needs some changes to accomdate the inheritance. | ||
|
||
When a syncd instance runs inside the gbsyncd docker, a new command line option --paiInstance or -i with an integer argument is required. A CommandLineOptions class variable m_paiInstance stores the argument value. The syncd instance in gbsyncd docker already uses another command line option -x to point the configuration file "gearbox\_config.json". The CommandLineOptions class variable m_contextConfig stores the configuration file name. | ||
|
||
The variable m_paiInstance can used as an index into the array of the "phys" section in the configuration file "gearbox\_config.json". There are JSON key/value of "phy\_id", "lib\_name", "phy\_access\_lib\_name" and "mdio\_cl22\_only" in the "phys" section. | ||
|
||
int syncd_main(int argc, char **argv) | ||
{ | ||
... | ||
if (commandLineOptions->m_paiInstance >= 0) { | ||
auto vendorSai = std::make_shared<VendorPai>(commandLineOptions->m_paiInstance, commandLineOptions->m_contextConfig); | ||
... | ||
} else { | ||
auto vendorSai = std::make_shared<VendorSai>(); | ||
... | ||
} | ||
... | ||
} | ||
|
||
For the case that multiple PHY ids aggregate in a single syncd context, it is a new separate topic. We don't discuss the topic in this HLD. | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Currently we are in the case of "multiple PHY ids aggregate in a single syncd context" by default. Need consider it for backwards compatibility. Even different cases could coexist. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. This design does not block other software components/changes to manage multiple PHYs in a single context. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. If There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. This design does not cover the PHY aggregation issue. When there is no PHY aggregation, each PHY will have its own context and each PHY is controlled by one gbsyncd process. Each gbsyncd process will have a different context. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Currently Broncos/Broadcom PAI for PikeZ is working with PHY aggregation, i.e. one gbsyncd process with one context manages multiple PHYs. This design should cover it. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Please refer to PR sonic-net/sonic-buildimage#11362, file device/arista/x86_64-arista_720dt_48s/Arista-720DT-48S/context_config.json. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I only see that context of a json file but I don't see the code processing the context. In order for us to adapt our design for the phy aggregation, we need to know how the context_config.json is processed and used. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. im not sure about idea passing globalContext to VendorSai since global context is concept of syncd and sairedis not VendorSai There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. maybe it would be good idea do ass PaiSai.cpp that will inherit VendorSai.cpp, and use selection in syncd_main.cpp where vendoisai would load dynamic SAI apis' and PaiSai would override those and prepare arguments in create switch function There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. We may add another command line options to specify PHY id. I will double check if global context is needed in VendorSai. Our existing code use VendorPaiDll class which inherits from VendorSai class. We found that we need to override most member functions but with a small change in each member function. We come to the conclusion that change VendorSai itself makes more sense. |
||
|
||
The VendorSai class needs to add all SAI API functions as function pointers, e.g. | ||
|
||
class VendorSai: | ||
public sairedis::SaiInterface | ||
{ | ||
public: | ||
... | ||
+ sai_status_t (*m_sai_api_initialize)(uint64_t flags, const sai_service_method_table_t *services); | ||
+ sai_status_t (*m_sai_api_uninitialize)(void); | ||
+ sai_status_t (*m_sai_api_query) (sai_api_t api, void **api_method_table); | ||
... | ||
} | ||
|
||
The VendorSai class constructor needs to assign all SAI API function names to the function pointers, e.g. | ||
|
||
VendorSai::VendorSai() | ||
{ | ||
... | ||
+ m_sai_api_initialize = sai_api_initialize; | ||
+ m_sai_api_uninitialize = sai_api_uninitialize; | ||
+ m_sai_api_query = sai_api_query; | ||
... | ||
} | ||
|
||
In VendorSai class member functions where the SAI API function is called, the function name is replaced with the function pointer, e.g. | ||
|
||
sai_status_t VendorPaiDLL::initialize( | ||
_In_ uint64_t flags, | ||
_In_ const sai_service_method_table_t *service_method_table) | ||
{ | ||
... | ||
- auto status = sai_api_initialize(flags, service_method_table); | ||
+ auto status = m_sai_api_initialize(flags, service_method_table); | ||
... | ||
} | ||
|
||
The information for PHY id, PAI library name, MDIO library name and MDIO mode can parsed from the JSON key of "phy\_id", "lib\_name", "phy\_access\_lib\_name" and "mdio\_cl22\_only" from the "phy" section of the configuration file "gearbox\_config.json". The VendorPai class constructor can use the information to initialize all the function pointers using dlopen()/dlsym(), e.g. | ||
|
||
#define MDIO_READ "mdio_read" | ||
#define MDIO_WRITE "mdio_write" | ||
#define MDIO_READ_CLAUSE22 "mdio_read_cl22" | ||
#define MDIO_WRITE_CLAUSE22 "mdio_write_cl22" | ||
|
||
VendorPai::VendorPai(int pai_instance, string gearbox_config) | ||
{ | ||
int phy_id; | ||
string pai_lib_name, string mdio_lib_name; | ||
bool cl22_only; | ||
... | ||
phy_id = parse_gearbox_config(pai_instance, gearbox_config).phy_id; | ||
pai_lib_name = parse_gearbox_config(pai_instance, gearbox_config).pai_lib_name; | ||
mdio_lib_name = parse_gearbox_config(pai_instance, gearbox_config).mdio_lib_name; | ||
cl22_only = parse_gearbox_config(pai_instance, gearbox_config).cl22_only; | ||
m_sai_dll_handle = dlopen (pai_lib_name.c_str(), RTLD_LAZY); | ||
*(void**)(&m_sai_api_initialize) = dlsym(m_sai_dll_handle, "sai_api_initialize"); | ||
*(void**)(&m_sai_api_uninitialize) = dlsym(m_sai_dll_handle, "sai_api_uninitialize"); | ||
*(void**)(&m_sai_api_query) = dlsym(m_sai_dll_handle, "sai_api_query"); | ||
... | ||
m_access_lib_handle = dlopen (mdio_lib_name.c_str(), RTLD_LAZY); | ||
m_mdio_cl22_only = cl22_only; | ||
... | ||
if (m_mdio_cl22_only) | ||
{ | ||
*(void**)(&m_mdio_read) = dlsym(m_access_lib_handle, MDIO_READ_CLAUSE22); | ||
} else { | ||
*(void**)(&m_mdio_read) = dlsym(m_access_lib_handle, MDIO_READ); | ||
} | ||
... | ||
if (m_mdio_cl22_only) | ||
{ | ||
*(void**)(&m_mdio_write) = dlsym(m_access_lib_handle, MDIO_WRITE_CLAUSE22); | ||
} else { | ||
*(void**)(&m_mdio_write) = dlsym(m_access_lib_handle, MDIO_WRITE); | ||
} | ||
... | ||
} | ||
|
||
Because only the PHY access library name can be changed in the configuration file, we define the PHY access function names always being "mdio\_read", "mdio_write", "mdio\_read\_cl22" and "mdio\_write\_cl22" for MDIO read and write of clause 45 and clause 22, respectively. The access function prototypes are already defined in the PAI library. | ||
|
||
The VendorPai::create() function can set the correct MDIO access functions for PAI in gbsyncd. | ||
|
||
sai_status_t VendorPai::create( | ||
_In_ sai_object_type_t objectType, | ||
_Out_ sai_object_id_t* objectId, | ||
_In_ sai_object_id_t switchId, | ||
_In_ uint32_t attr_count, | ||
_In_ const sai_attribute_t *attr_list) | ||
{ | ||
... | ||
if (objectType == SAI_OBJECT_TYPE_SWITCH) | ||
{ | ||
std::vector<sai_attribute_t> attr_copy; | ||
sai_attribute_t attr; | ||
|
||
for (auto i = 0; i < attr_count; i++) | ||
Comment on lines
+226
to
+231
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. im not sure it this should be handled here, or in syncd itself, since vendor sai should be just thin layer on SAI apis, and not interfering with attributes There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. We will change to handle in syncd itself. |
||
{ | ||
if (attr_list[i].id == SAI_SWITCH_ATTR_REGISTER_READ && m_context !=0) | ||
{ | ||
attr.id = SAI_SWITCH_ATTR_REGISTER_READ; | ||
attr.value.ptr = (void *) m_mdio_read; | ||
attr_copy.push_back(attr); | ||
} | ||
else if (attr_list[i].id == SAI_SWITCH_ATTR_REGISTER_WRITE) | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. should here be also && m_context !=0 ? There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Actually SAI_SWITCH_ATTR_REGISTER_WRITE and SAI_SWITCH_ATTR_REGISTER_READ attributes are only passed by orchagent for PAI but not for SAI. As my answer to another comment, we are going to move this piece of code from VendorSai to syncd itself. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. maybe there should be ParSay inheriting VendorSai to keep this separate from Syncd.cpp class There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. We will create VendorPaiDll inheriting VendorSai. We still need a small change inside VendorSai so that VendorPaiDll does not have to override most the member function. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. yes |
||
{ | ||
attr.id = SAI_SWITCH_ATTR_REGISTER_WRITE; | ||
attr.value.ptr = (void *) m_mdio_write ; | ||
attr_copy.push_back(attr); | ||
} | ||
else | ||
{ | ||
attr_copy.push_back(attr_list[i]); | ||
} | ||
} | ||
sai_attribute_t *attr_array = attr_copy.data(); | ||
auto status = info->create(&mk, switchId, attr_count, attr_array); | ||
... | ||
} | ||
else | ||
{ | ||
auto status = info->create(&mk, switchId, attr_count, attr_list); | ||
... | ||
} | ||
... | ||
} | ||
|
||
### SAI API | ||
|
||
When a switch platform with external PHY is connected to the MDIO bus from the switch NPU, the external PHY is accessed through the SAI and syncd. The existing SAI switch api already has mdio access functions switch\_mdio\_read and switch\_mdio\_write defined, but it does not distinguish the Clause 45 mdio from the Clause 22 mdio. New mdio access functions switch\_mdio\_cl22\_read and switch\_mdio\_cl22\_write are added to the SAI switch api to handle the Clause 22 mdio only. | ||
|
||
typedef struct _sai_switch_api_t | ||
{ | ||
sai_create_switch_fn create_switch; | ||
sai_remove_switch_fn remove_switch; | ||
... | ||
sai_switch_mdio_read_fn switch_mdio_read; | ||
sai_switch_mdio_write_fn switch_mdio_write; | ||
... | ||
+ sai_switch_mdio_cl22_read_fn switch_mdio_cl22_read; | ||
+ sai_switch_mdio_cl22_write_fn switch_mdio_cl22_write; | ||
} sai_switch_api_t; | ||
|
||
For backward compatibility of the SAI API before above change, the Clause 22 mdio device can still be accessed using the existing mdio access functions together with extra configuration in NPU SAI/SDK or experimental switch attribute. For example, new SAI soc property is added to the config.bcm file for a switch platform with external PHY using the Clause 22 mdio registers: | ||
|
||
device/arista/x86_64-arista_720dt_48s/td3x2-a720dt-48s-flex.config.bcm: | ||
... | ||
+sai_mdio_access_clause22=1 | ||
|
||
### Configuration and management | ||
Each device with external PHY should have a configuration file gearbox_config.json. One JSON key "lib\_name" has the value of the PAI library name. We add 2 more JSON keys. One new JSON key "phy\_access\_lib\_name" has the value of the mdio access library name. The other new JSON key "mdio\_cl22\_only" indicates the PHY device using clause 22 mdio. | ||
|
||
gearbox_config.json: | ||
|
||
"phys": [ | ||
{ | ||
"phy_id": 1, | ||
... | ||
"lib_name": "/usr/lib/libpai_layer.so", | ||
... | ||
"phy_access": "mdio", | ||
+ "phy_access_lib_name": "/usr/lib/libgbsyncdaccess.so", | ||
+ "mdio_cl22_only": true, | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Instead of a boolean key, I prefer to explicitly specify mdio access method, like
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Because MDIO clause 22 could access clause 45 register but not vice versa. The MDIO clause 22 register is often referred as clause 22 access only register. |
||
... | ||
} | ||
], | ||
|
||
### Restrictions/Limitations | ||
When the external PHY is connected to the MDIO bus from the switch NPU, this design only applies to the device with Broadcom SAI/NPU. When external PHY is connected to the FPGA/CPLD based mdio controller, this design should work for all device. | ||
|
||
When external PHY is using broadcast firmware download method, there might be requirements of other software components and helper depends on the PAI library implementation. It is outside the scope of this HLD. | ||
|
||
### Testing Requirements/Design | ||
The added MDIO IPC server class and the changed VendorSai class are in the syncd process. Some unit test cases can be added to the existing syncd unit test. Some system test cases can only be done on systems with the external PHY and NPU mdio bus. | ||
|
||
#### Unit Test cases | ||
The MDIO IPC server class only invokes some class methods when there are unix socket connection and valid MDIO IPC client messages on the unix socket. New gtest cases will be added to the syncd unit test simulating the MDIO IPC client. | ||
|
||
The 4 new methods added to the VendorSai class and its parent class SaiInterface only works on the SAI with real hardware, i.e. a systems with the external PHY and NPU mdio bus. | ||
|
||
virtual sai_status_t switchMdioRead(...); | ||
virtual sai_status_t switchMdioWrite(...); | ||
virtual sai_status_t switchMdioCl22Read(...); | ||
virtual sai_status_t switchMdioCl22Write(...); | ||
|
||
Hence the MockableSaiInterface class and its parent class DummySaiInterface will override the above 4 methods. | ||
|
||
#### System Test cases | ||
On a system with the external PHY connected to NPU mdio bus, we can use 'socat' simulating the IPC client as an interactive command line shell to access the PHY mdio registers, e.g. | ||
|
||
docker exec -it syncd socat - UNIX-CONNECT:/var/run/sswsyncd/mdio-ipc.srv | ||
|
||
Command in the shell to read MDIO clause 45 register at an address and an offset: | ||
|
||
mdio <address> <reg offset> | ||
|
||
Command in the shell to write MDIO clause 45 register at an address and an offset with a value: | ||
|
||
mdio <address> <reg offset> <value> | ||
|
||
Command in the shell to read MDIO clause 22 register at an address and an offset: | ||
|
||
mdio-cl22 <address> <reg offset> | ||
|
||
Command in the shell to write MDIO clause 22 register at an address and an offset with a value: | ||
|
||
mdio-cl22 <address> <reg offset> <value> | ||
|
||
Command to exit from the interactive command line shell: | ||
|
||
Ctrl+D |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
In switch hardware arch of sonic, one realistic assumption is that multiple external PHYs connecting to one ASIC/NPU, are same chip type. This simplifies software design. Like one syncd docker having one SAI library, one gbsyncd docker includes one PAI library for multiple PHYs.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Not necessary true. Two counterexamples come to mind: Dell 3248pxe and Accton as4630-54NPE.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Are the PHYs from one Vendor? If yes, can be driven by one PAI libary?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Dell 3248pxe has PHYs from 2 different vendors.