The core component: SNMP Devices. The user will define Devices to poll data from using SNMP protocol.
Configured SNMP Devices are shown as table. This will appear every time you navigate from menu.
-
Add: In the SNMP Devices list click on new button
-
Edit: Click on SNMP Devices edit's button
The Create/Modify form will show up:
Type of settings | Config Parameter | Description |
---|---|---|
Core settings | ID | Text String that uniquely identify the device , should be unique in the config db, it can be hostname, serial number or any other text id |
Active | let device begin gathering process on agent boot process | |
Device settings | Host | the network direction the agent will use to do snmp connection , could be IP or fqdn name |
Port | the network port where the agent will use to do snmp connections | |
Timeout | sets de timeout for each SNMP query | |
Retries | sets the number of retries to attempt within Timeout | |
Alternate System OID's | Set OID to get like MIB-2::System Info for non MIB-2 based devices | |
Debug settings | LogLevel | enable use select verbosity of the device log |
SnmpDebug | if this option is set all snmp low level protocol queries with detailed info on this device will be written on a file with name "snmpdebug_XXXXXX.log" | |
Polling settings | Snmpversion | could be any of these [1,2c,3] |
Disable snmpbulk | if true the bulk feature won't be used ( these feature is needed to query IBM XIV disk arrays, which has a snmpv2/v3 agent with a buggy bulk support) | |
MaxRepetitions | set The MaxRepetitions parameter for BULKWALK SNMP queries | |
Community | the snmp version 2 community | |
v3seclevel | (only for snmpv3) define the level of security needed for the connection valid values are.
|
|
v3authuser | (snmpv3 only) the username that will establish the snmp query | |
v3authpass | (snmpv3 only) the authentication password | |
v3authprot | (snmpv3 only) the Authentication Protocol values should be any of "MD5", "SHA" | |
v3privpass | (snmpv3 only) Privacy password | |
v3privprot | (snmpv3 only) Privacy Protocol values should be any of [ "DES", "AES"] | |
v3ContextEngineID | SNMPV3 ContextEngineID in ScopedPDU (equivalent to the net-snmp -E paramenter) | |
v3ContextName | SNMPV3 ContextName in ScopedPDU ( equivalent to the net-snmp -n parameter) | |
Freq | Frequency of polling in seconds ( default 60 sec if not set) | |
UpdateFltFreq | Number pof complete polls that agent will wait before perform snmp table index/filter updates , the final update time will be Freq*FilterUpdate ( in seconds) Default 60 ( 1h elapsed time) | |
ConcurrentGather | Open a new SNMP Connection for each measurement and send concurrent queries over the device. | |
Data settings | InfluxDB Server | let you select over which database you will send data. |
DeviceTagName | Tag name the agent will send to the output db (default : "device"), could be any of the other more explicit tagname depending on the device type, context , by example (router,switch,firewall,dns..etc) | |
DeviceTagValue | could be one of these:
|
|
ExtraTags | an array of tags for this device that will be sent on all its measurements. | |
Override Device Vars | List of var catalog to override the default set value | |
Measurement Groups | an array of Measurement Group ID. | |
Measurement Filters | an array for configured filters | |
Extra settings | Description | add here all important information over this device |
When editing or adding a SNMPDevice there is the option to send a query and check its connectivity and send OID queries from already defined components.
To access on the Test Connection Modal, click on Test Connection
The user can select the OID Source
:
The OID related on selected component will load and the user will be able to send query to see those results:
As the user is editing or adding a new Device it a Custom Filter can be created directly from its form. To access, click on "Filter Connection" button and the form will shown up.
For more information, check Component: Custom Filters
Multi edit has 3 options: Remove,Change property or Append Property
-
Remove: Allows to remove all the selected items
-
Change property: Allows to change the selected property of all the selected items. The properties are the same defined in the configuration.
Property | Type | Options/Values |
---|---|---|
Active | Selector | True /False |
LogLevel | Selector | Panic/ Fatal/ Error/ Warning/ Info /Debug |
Concurrent Gather | Selector | True /False |
Disable Bulk | Selector | True /False |
SNMPDebug | Selector | True /False |
Timeout | Input | Time in seconds |
Retries | Input | Any number |
Freq | Input | Any number in Hz |
Max Repetitions | Input | Any number |
Device Tag Name | Input | Any string |
MeasurementGroup | Selector | List of all measurement groups |
MeasFilters | Selector | List of all the filters |
ExtraTags | Input | Any tag (string) |
- Append Property: Allows to append a new measurement, filter o extra tags in the selected devices.
Property | Type | Options/Values |
---|---|---|
MeasurementGroup | Selector | List of all measurement groups |
MeasFilters | Selector | List of all the filters |
ExtraTags | Input | Any tag (string) |