AD EG is an attack/decay envelope generator with forward and reverse trigger inputs, and end-of-cycle trigger output.

I/O

1/3 2/4
Trig (Digital) Triggers the AD envelope Triggers the envelope in reverse (DA)
CV In Attack modulation (bipolar) Decay modulation (bipolar)
Output Envelope End of Cycle trigger

Note that triggering the envelope in reverse does not change the CV modulation controls, meaning that CV 1 controls the effective "attack" segment regardless of direction.

UI Parameters

  • Attack duration
  • Decay Duration

Adapted from AD-EG © 2018-2022, Jason Justian and Beige Maze Laboratories.